Variability in radiation dose and image quality: A comparison across fluoroscopy-system vendors, generations of equipment and institutions

Catheter Cardiovasc Interv. 2018 Dec 1;92(7):E471-E477. doi: 10.1002/ccd.27793. Epub 2018 Sep 12.

Abstract

Objectives: To evaluate differences in radiation dose and image quality across institutions, fluoroscope vendors and generations of fluoroscopes for pediatric cardiac catheterization.

Background: Increased recognition of the potentially harmful effects of ionizing radiation has spurred technological advances in fluoroscopes, as well as increased focus on optimizing fluoroscope performance. There is currently little understanding of variability in the dose-image quality relationship across institutions, fluoroscope vendor and/or generation of equipment.

Methods: We evaluated latest generation fluoroscopes from Phillips, Siemens, GE, and Toshiba, and an older generation Phillips fluoroscope (release date 2003) at three different institutions. Radiation dose was measured using an anthropomorphic dose-assessment phantom with effective dose in mSv estimated from Monte Carlo simulations. Image quality phantom images were scored on a 12-point scale by three blinded reviewers.

Results: Fluoroscope effective doses ranged from 0.04 to 0.14 mSv/1,000 pulses for fluoroscopy with associated composite image quality scores ranging from 8.0 ± 0.6 to 10.4 ± 1.3. For cineangiography, effective doses ranged from 0.17 to 0.57 mSv/1,000 frames with image quality scores ranging from 10.1 ± 0.3 to 11.1 ± 0.3. There was modest correlation between effective dose and image quality (r = 0.67, P = 0.006). The older generation fluoroscope delivered consistently higher doses than the newer generation systems (2.3- to 3.5-fold higher for fluoroscopy; 1.1- to 3.4-fold higher for cineangiography) without appreciable differences in image quality.

Conclusion: Technological advances have markedly improved fluoroscope performance. Comparing latest generation systems across vendors and institutions, we found variability in the dose-IQ relationship and speculate that this reflects both equipment and institutional optimization practices.

Keywords: effective dose; fluoroscopy; image quality; institutional variability.

Publication types

  • Comparative Study
  • Multicenter Study
  • Research Support, N.I.H., Extramural

MeSH terms

  • Cardiac Catheterization / adverse effects
  • Cardiac Catheterization / instrumentation*
  • Cineangiography / adverse effects
  • Cineangiography / instrumentation*
  • Computer Simulation
  • Coronary Angiography / adverse effects
  • Coronary Angiography / instrumentation*
  • Equipment Design
  • Fluoroscopy / instrumentation
  • Humans
  • Monte Carlo Method
  • Phantoms, Imaging
  • Predictive Value of Tests
  • Radiation Dosage*
  • Radiation Exposure* / adverse effects
  • Radiation Monitoring
  • Radiography, Interventional / adverse effects
  • Radiography, Interventional / instrumentation*
  • Reproducibility of Results