Diagnostic Utility of Complement Serology for Atypical Hemolytic Uremic Syndrome

Mayo Clin Proc. 2018 Oct;93(10):1351-1362. doi: 10.1016/j.mayocp.2018.07.008.

Abstract

Objective: To investigate the clinical utility of a 9-analyte complement serology panel (COMS) covering complement function (CH50 and AH50), components (C3, C4), factor B (CFB), factor H, and activation markers (C4d, Bb, and soluble membrane attack complex) for the diagnosis of atypical hemolytic uremic syndrome (aHUS).

Methods: Physician orders for COMS from January 19, 2015, through November 4, 2016, were reviewed. Demographic characteristics, patient diagnosis, and laboratory parameters were recorded.

Results: There were 177 COMS orders for 147 patients. The median patient age was 44.9 years (range, 0.9-88.0 years). Common reasons for ordering COMS included monitoring and diagnosis of C3 glomerulopathy and renal dysfunction and differentiation of aHUS from other thrombotic microangiopathies (TMAs). Forty-four patients had COMS ordered for TMAs: 8 had aHUS and all had 1 or more abnormalities within the alternative pathway of complement. Although the sensitivity of this finding for the diagnosis of aHUS is 100%, the specificity is only 28%, with a positive likelihood ratio of 1.39. Patients with aHUS had lower CH50, C3, and CFB than did those with secondary non-aHUS TMA (all P<.01). A combined CFB of 20.9 mg/dL or less and CH50 of 56% or less led to sensitivity of 75% with increased specificity of 88.9% and a diagnostic odds ratio of 24.

Conclusion: A COMS abnormality should not be interpreted in isolation. In conjunction with clinical presentation, a decrease in both CFB and CH50 may be an important clue to support the diagnosis of aHUS.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adult
  • Atypical Hemolytic Uremic Syndrome* / diagnosis
  • Atypical Hemolytic Uremic Syndrome* / immunology
  • Clinical Laboratory Information Systems / statistics & numerical data
  • Complement Activation / immunology*
  • Complement Hemolytic Activity Assay* / methods
  • Complement Hemolytic Activity Assay* / statistics & numerical data
  • Complement System Proteins / immunology*
  • Diagnosis, Differential
  • Female
  • Humans
  • Male
  • Monitoring, Immunologic / methods*
  • Reproducibility of Results
  • Sensitivity and Specificity
  • Thrombotic Microangiopathies / diagnosis

Substances

  • Complement System Proteins