[Computer aided design and three-dimensional printing for apicoectomy guide template]

Beijing Da Xue Xue Bao Yi Xue Ban. 2018 Oct 18;50(5):905-910.
[Article in Chinese]

Abstract

Objective: To establish an apicoectomy guide template design and manufacturing method, based on multi-source data fusion, computer aided design (CAD) and fused deposition modeling (FDM). The feasibility of the guide template was preliminary evaluated by the in vitro model experiment.

Methods: An extracted upper anterior tooth, after root canal treatment, was optical scanned, after which the extracted upper anterior tooth was poured in an apicoectomy plaster model. Cone-beam computed tomography (CBCT) scanning of the apicoectomy plaster model was performed, after which optical scanning of the plaster model for apical resection surgery was carried out. All of the relevant CBCT and optical scanning data of the extracted upper anterior tooth and the apicoectomy plaster model were introduced into the Geomagic Studio 2012 software. The multi-source data fusion technology was used to virtually simulate the three-dimensional positional relationship of the extracted tooth, the dentition, the alveolar bone and the gingival, based on which, the three-dimensional design of the apicoectomy guide template was completed in the Geomagic Studio 2012 software. With the technology of fused deposition modeling, the apical resection surgical guide template was three-dimensionally printed with the material of polylactic acid (PLA). Under the guidance of the surgical guide template, the root apical resection was performed on the plaster model. After the apicoectomy, the extracted upper anterior tooth was taken off from the apicoectomy plaster model and then was given the optical scanning. The apical resection length and angle were calculated by the function of distance measurement and angle measurement, and the results were compared with the preset values.

Results: The length of the apical resection was 2.88 mm along the direction of the long axis of the tooth, which was 0.12 mm lower than the preset 3 mm. The included angle between the apical resection plane and the long axis of the tooth was 77.9°, 12.1° lower than the preset 90°.

Conclusion: This study successfully established a digital design and production method of apicoectomy guide template by combing the multi-source data fusion, CAD and FDM technology. The design route and the production method are feasible. The study will provide a technology and methodology reference for the development of domestic special software for the digital design of apicoectomy guide template.

MeSH terms

  • Apicoectomy* / methods
  • Computer-Aided Design*
  • Cone-Beam Computed Tomography
  • Printing, Three-Dimensional*
  • Software