7-year results of primary total hip arthroplasty with the uncemented Avenir stem

Hip Int. 2019 Jul;29(4):418-423. doi: 10.1177/1120700018810211. Epub 2018 Nov 11.

Abstract

Aims: The aim of the present study was to evaluate the 7-year functional outcome and radiographic results of primary total hip arthroplasties (THAs) performed with the uncemented Avenir stem.

Patients and methods: Between January 2006 and October 2008, 100 consecutive primary hips in 92 patients were enrolled at 2 centres. The mean age at operation was 58.5 years (27-87 years). Mini-incision (50%) and standard approaches (50%) were used to implant 22 standard and 78 lateralised stems.

Results: The 7-year Kaplan-Meier survival rate was 98.9% (95% CI, 92.9-99.8) with stem revision for any reason as endpoint. No stem related complications occurred. 1 stem revision was due to deep infection at 51 months post-op. We had 4 acetabular revisions. The mean Harris Hip Score (HHS) at 7 years follow-up was 93.1 points (60-100). Radiographic analysis showed 2 patients had non-progressive radiolucent lines and no patient had any signs of stem subsidence or loosening.

Conclusion: The 7-year implant survival and the functional outcomes for THA performed with the study device are excellent and were in line with those documented for comparable contemporary uncemented fully HA-coated stems. Longer term follow-up of this consecutive series needs to be performed.

Keywords: Aseptic loosening; cohort follow-up; hip arthroplasty; primary hip replacement; uncemented stem.

MeSH terms

  • Acetabulum
  • Adult
  • Aged
  • Arthroplasty, Replacement, Hip* / instrumentation
  • Arthroplasty, Replacement, Hip* / methods
  • Female
  • Follow-Up Studies
  • Hip Prosthesis
  • Humans
  • Male
  • Middle Aged
  • Prosthesis Design*
  • Prosthesis Failure
  • Reoperation
  • Survival Rate
  • Treatment Outcome