Displaced humeral surgical neck fractures: classification and results of third-generation percutaneous intramedullary nailing

J Shoulder Elbow Surg. 2019 Feb;28(2):276-287. doi: 10.1016/j.jse.2018.07.010. Epub 2018 Nov 12.

Abstract

Background: The high rates of complications and reoperations observed with the early designs of first-generation (unlocked) and second-generation (bent design) humeral intramedullary nail (IMNs) have discouraged their use by most surgeons. The purpose of this study was to report the results of a third-generation (straight, locking, low-profile, tuberosity-based fixation) IMN, inserted through a percutaneous approach, for the treatment of displaced 2-part surgical neck fractures.

Methods: We performed a retrospective review of 41 patients who underwent placement of a third-generation IMN to treat a displaced 2-part surgical neck fracture (AO/OTA type 11A3). The mean age at surgery was 57 years (range, 17-84 years). After percutaneous insertion through the humeral head, the IMN was used as a reduction tool. Static locking fixation was achieved after axial fracture compression ("back-slap" hammering technique). Patients were reviewed and underwent radiography with a minimum of 1 year of follow-up; the mean follow-up period was 26 months (range, 12-53 months).

Results: Preoperatively, 3 types of surgical neck fractures were observed: with valgus head deformity (Type A = 8 cases), shaft translation without head deformity (Type B = 19 cases), or with varus head deformity (Type C = 14 cases). At final follow-up, all fractures went on to union, and the mean humeral neck-shaft angle was 132° ± 5°. We observed 2 malunions and 1 case of partial humeral head avascular necrosis. No cases underwent screw migration or intra-articular penetration. At last review, mean active forward elevation was 146° (range, 90°-180°) and mean external rotation was 50° (range, 20°-80°). The mean Constant-Murley score and Subjective Shoulder Value were 71 (range, 43-95) and 80% (range, 50%-100%), respectively.

Conclusions: Antegrade insertion of a third-generation IMN through a percutaneous approach provides a high rate of fracture healing, excellent clinical outcome scores, and a low rate of complications. No morbidity related to the passage of the nail through the supraspinatus muscle and the cartilage was observed. The proposed A, B, and C classification allows choosing the optimal entry point for intramedullary nailing.

Keywords: Two-part fractures; intramedullary (IM) locking nail; proximal humeral fracture; proximal humeral nail; surgical neck fractures; third-generation humeral nail.

MeSH terms

  • Adolescent
  • Adult
  • Aged
  • Aged, 80 and over
  • Bone Nails*
  • Female
  • Follow-Up Studies
  • Fracture Fixation, Intramedullary / adverse effects
  • Fracture Fixation, Intramedullary / instrumentation*
  • Fracture Fixation, Intramedullary / methods*
  • Fracture Healing
  • Humans
  • Male
  • Middle Aged
  • Range of Motion, Articular
  • Retrospective Studies
  • Shoulder Fractures / classification*
  • Shoulder Fractures / diagnostic imaging
  • Shoulder Fractures / physiopathology
  • Shoulder Fractures / surgery*
  • Treatment Outcome
  • Young Adult