Tomographic and Biomechanical Scheimpflug Imaging for Keratoconus Characterization: A Validation of Current Indices

J Refract Surg. 2018 Dec 1;34(12):840-847. doi: 10.3928/1081597X-20181012-01.

Abstract

Purpose: To analyze the potential benefit of the newly developed Tomography and Biomechanical Index (TBI) for early keratoconus screening.

Methods: In this retrospective study, the discriminatory power of the corneal tomography Belin/Ambrósio Enhanced Ectasia Display (BAD-D) index and the newly developed Corvis Biomechanical Index (CBI) and TBI to differentiate between normal eyes, manifest keratoconus eyes (KCE), very asymmetric keratoconus eyes with ectasia (VAE-E), and their fellow eyes with either regular topography (VAE-NT) or regular topography and tomography (VAE-NTT) were analyzed by applying the t test (for normal distribution), Wilcoxon matched-pairs test (if not normally distributed), and receiver operating characteristic curve (ROC). The DeLong test was used to compare the area under the ROC (AUROC). Further, the cut-offs of the analyzed indices presented in a study by Ambrósio et al. from 2017 were applied in the study population to enable a cross-validation in an independent study population.

Results: All indices demonstrated a high discriminative power when comparing normal and advanced keratoconus, which decreased when comparing normal and VAE-NT eyes and further when analyzing normal versus VAE-NTT eyes. The difference between the AUROCs reached a statistically significant level when comparing TBI versus BAD-D analyzing normal versus all included keratoconic eyes (P = .02). The TBI presented with the highest AUROCs throughout all conducted analyses when comparing different keratoconus stages, although not reaching a statistically significant level. Applying the cut-offs presented by Ambrósio et al. to differentiate between normal and VAE-NT in the study population, the accuracy was reproducible (accuracy in our study population with an optimized TBI cut-off: 0.72, with the cut-off defined by Ambrósio et al. 0.67).

Conclusions: The TBI enables karatoconus screening in topographical and tomographical regular keratoconic eyes. To further improve the screening accuray, prospective studies should be conducted. [J Refract Surg. 2018;34(12):840-847.].

Publication types

  • Validation Study

MeSH terms

  • Adult
  • Biomechanical Phenomena
  • Cornea / physiopathology*
  • Corneal Pachymetry
  • Corneal Topography
  • Elasticity / physiology*
  • Female
  • Humans
  • Keratoconus / diagnostic imaging*
  • Keratoconus / physiopathology*
  • Male
  • ROC Curve
  • Retrospective Studies
  • Tomography