Prediction of Core Body Temperature Based on Skin Temperature, Heat Flux, and Heart Rate Under Different Exercise and Clothing Conditions in the Heat in Young Adult Males
- PMID: 30618795
- PMCID: PMC6295644
- DOI: 10.3389/fphys.2018.01780
Prediction of Core Body Temperature Based on Skin Temperature, Heat Flux, and Heart Rate Under Different Exercise and Clothing Conditions in the Heat in Young Adult Males
Abstract
Non-invasive, multi-parameter methods to estimate core body temperature offer several advantages for monitoring thermal strain, although further work is required to identify the most relevant predictor measures. This study aimed to compare the validity of an existing and two novel multi-parameter rectal temperature prediction models. Thirteen healthy male participants (age 30.9 ± 5.4 years) performed two experimental sessions. The experimental procedure comprised 15 min baseline seated rest (23.2 ± 0.3°C, 24.5 ± 1.6% relative humidity), followed by 15 min seated rest and cycling in a climatic chamber (35.4 ± 0.2°C, 56.5 ± 3.9% relative humidity; to +1.5°C or maximally 38.5°C rectal temperature, duration 20-60 min), with a final 30 min seated rest outside the chamber. In session 1, participants exercised at 75% of their heart rate maximum (HR max) and wore light athletic clothing (t-shirt and shorts), while in session 2, participants exercised at 50% HR max, wearing protective firefighter clothing (jacket and trousers). The first new prediction model, comprising the input of 18 non-invasive measures, i.e., insulated and non-insulated skin temperature, heat flux, and heart rate ("Max-Input Model", standard error of the estimate [SEE] = 0.28°C, R2 = 0.70), did not exceed the predictive power of a previously reported model which included six measures and no insulated skin temperatures (SEE = 0.28°C, R2 = 0.71). Moreover, a second new prediction model that contained only the two most relevant parameters (heart rate and insulated skin temperature at the scapula) performed similarly ("Min-Input Model", SEE = 0.29, R2 = 0.68). In conclusion, the "Min-Input Model" provided comparable validity and superior practicality (only two measurement parameters) for estimating rectal temperature versus two other models requiring six or more input measures.
Keywords: core body temperature; exercise; heart rate; heat flux; heat strain; prediction model; rectal temperature; skin temperature.
Figures
Similar articles
-
Prediction of Core Body Temperature from Multiple Variables.Ann Occup Hyg. 2015 Nov;59(9):1168-78. doi: 10.1093/annhyg/mev054. Epub 2015 Aug 12. Ann Occup Hyg. 2015. PMID: 26268995
-
Monitoring heat strain: the effect of sensor type and location on single-site and mean skin temperature during work in the heat.Int Arch Occup Environ Health. 2021 Apr;94(3):539-546. doi: 10.1007/s00420-020-01600-y. Epub 2020 Nov 13. Int Arch Occup Environ Health. 2021. PMID: 33184687
-
Increased Air Velocity Reduces Thermal and Cardiovascular Strain in Young and Older Males during Humid Exertional Heat Stress.J Occup Environ Hyg. 2015;12(9):625-34. doi: 10.1080/15459624.2015.1029613. J Occup Environ Hyg. 2015. PMID: 25897617
-
Effects of endurance training and heat acclimation on psychological strain in exercising men wearing protective clothing.Ergonomics. 1998 Mar;41(3):328-57. doi: 10.1080/001401398187071. Ergonomics. 1998. PMID: 9520629 Clinical Trial.
-
Work-rest regimens for work in hot environments: A scoping review.Am J Ind Med. 2024 Apr;67(4):304-320. doi: 10.1002/ajim.23569. Epub 2024 Feb 12. Am J Ind Med. 2024. PMID: 38345435 Review.
Cited by
-
Artificial Intelligence-Powered Electronic Skin.Nat Mach Intell. 2023 Dec;5(12):1344-1355. doi: 10.1038/s42256-023-00760-z. Epub 2023 Dec 18. Nat Mach Intell. 2023. PMID: 38370145
-
Cardiorespiratory Sensors and Their Implications for Out-of-Hospital Cardiac Arrest Detection: A Systematic Review.Ann Biomed Eng. 2024 Feb 15. doi: 10.1007/s10439-024-03442-y. Online ahead of print. Ann Biomed Eng. 2024. PMID: 38358559 Review.
-
Thermoregulation during Field Exercise in Horses Using Skin Temperature Monitoring.Animals (Basel). 2023 Dec 30;14(1):136. doi: 10.3390/ani14010136. Animals (Basel). 2023. PMID: 38200867 Free PMC article.
-
Effects of heat and personal protective equipment on thermal strain in healthcare workers: part B-application of wearable sensors to observe heat strain among healthcare workers under controlled conditions.Int Arch Occup Environ Health. 2024 Jan;97(1):35-43. doi: 10.1007/s00420-023-02022-2. Epub 2023 Nov 10. Int Arch Occup Environ Health. 2024. PMID: 37947815 Free PMC article.
-
Free-living core body temperature monitoring using a wrist-worn sensor after COVID-19 booster vaccination: a pilot study.Biomed Eng Online. 2023 Mar 13;22(1):25. doi: 10.1186/s12938-023-01081-3. Biomed Eng Online. 2023. PMID: 36915134 Free PMC article.
References
-
- ACGIH (2017). TLVs and BEIs: Threshold Limit Values for Chemical Substances and Physical Agents and Biological Exposure Indices. Cincinnati, OH: American Conference of Governmental Industrial Hygienists.
LinkOut - more resources
Full Text Sources
Other Literature Sources