Validity and reliability of lower-limb pulse-wave velocity assessments using an oscillometric technique
- PMID: 30770607
- DOI: 10.1113/EP087444
Validity and reliability of lower-limb pulse-wave velocity assessments using an oscillometric technique
Abstract
New findings: What is the central question of this study? There is growing interest in the effects of sedentarism on central and peripheral cardiovascular health. To permit further investigation, including larger epidemiological studies, there is a need to identify arterial health assessment tools that are valid (accurate) and reliable (precise), yet practical. What is the main finding and its importance? Lower-limb vascular health (femoral-ankle pulse-wave velocity) can be determined in a supine position with accuracy and precision using an oscillometrically based device. This technology might help to improve our understanding of the pathological mechanisms linking cardiovascular disease to sedentarism, including the interaction between peripheral and central vasculature.
Abstract: There is a growing interest in the deleterious effects of sedentary behaviour on lower-limb arterial health. To permit further investigation, including larger epidemiological studies, there is a need to identify lower-limb arterial health assessment tools that are valid and reliable, yet simple to administer. In this study, we sought to determine the validity and between-day reliability of femoral-ankle pulse-wave velocity (faPWV) measures obtained using an oscillometrically based device (SphygmocCor XCEL) in supine and seated positions. Doppler ultrasound was used as the criterion. A total of 47 healthy adults were recruited for validity (n = 32) and reliability (n = 15) analyses. Validity was determined by measuring faPWV in seated and supine positions using the XCEL and Doppler ultrasound devices, in a randomized order. Between-day reliability was determined by measuring seated and supine faPWV using the XCEL on three different mornings, separated by a maximum of 7 days. The validity criterion [absolute standard error of estimate (aSEE) < 1.0 m s-1 ] was met in the supine [aSEE = 0.8 m s-1 , 95% confidence interval (CI) 0.4-1.0], but not in the seated (aSEE = 1.2 m s-1 , 95% CI 1.1-1.2) position. Intraclass correlation coefficient (ICC) estimates revealed that the XCEL demonstrated good reliability in the supine position (ICC = 0.83, 95% CI 0.65-0.93), but poor reliability in the seated position (ICC = 0.29, 95% CI 0.23-0.63). The oscillometric XCEL device can be used to determine lower-limb pulse-wave velocity with acceptable validity and reliability in the conventionally recommended supine position, but not in the seated position.
Keywords: Doppler ultrasound; arterial stiffness; posture; pulse-wave analysis.
© 2019 The Authors. Experimental Physiology © 2019 The Physiological Society.
Similar articles
-
Validity of single-point assessments for determining leg pulse wave velocity in sitting and supine positions.Clin Physiol Funct Imaging. 2020 May;40(3):157-164. doi: 10.1111/cpf.12616. Epub 2020 Jan 30. Clin Physiol Funct Imaging. 2020. PMID: 31880855
-
Reliability of oscillometric central blood pressure and central systolic loading in individuals over 50 years: Effects of posture and fasting.Atherosclerosis. 2018 Feb;269:79-85. doi: 10.1016/j.atherosclerosis.2017.12.030. Epub 2017 Dec 27. Atherosclerosis. 2018. PMID: 29339276
-
Reliability of oscillometric central blood pressure and wave reflection readings: effects of posture and fasting.J Hypertens. 2015 Aug;33(8):1588-93. doi: 10.1097/HJH.0000000000000604. J Hypertens. 2015. PMID: 26136065
-
Current assessment of pulse wave velocity: comprehensive review of validation studies.J Hypertens. 2019 Aug;37(8):1547-1557. doi: 10.1097/HJH.0000000000002081. J Hypertens. 2019. PMID: 30882597 Review.
-
Arterial wall elasticity: state of the art and future prospects.Diagn Interv Imaging. 2013 May;94(5):561-9. doi: 10.1016/j.diii.2013.01.025. Epub 2013 Apr 22. Diagn Interv Imaging. 2013. PMID: 23619291 Review.
Cited by
-
Effect of home-based, overground robotic-assisted gait training on vascular health in people with chronic stroke.Front Neurol. 2023 Mar 10;14:1093008. doi: 10.3389/fneur.2023.1093008. eCollection 2023. Front Neurol. 2023. PMID: 36970545 Free PMC article.
-
Localized activity attenuates the combined impact of a high fat meal and prolonged sitting on arterial stiffness: A randomized, controlled cross-over trial.Front Physiol. 2023 Feb 1;14:1107456. doi: 10.3389/fphys.2023.1107456. eCollection 2023. Front Physiol. 2023. PMID: 36818445 Free PMC article.
-
Acute sedentary behavior and cardiovascular disease research: standardizing the methodological posture.Am J Physiol Heart Circ Physiol. 2023 Jan 1;324(1):H122-H125. doi: 10.1152/ajpheart.00492.2022. Epub 2022 Dec 16. Am J Physiol Heart Circ Physiol. 2023. PMID: 36525481 Free PMC article.
-
Protocol for a study on Sitting with Interruption and Whole-Body Cardiovascular Health (SWITCH) in middle-aged adults.Contemp Clin Trials. 2023 Feb;125:107048. doi: 10.1016/j.cct.2022.107048. Epub 2022 Dec 9. Contemp Clin Trials. 2023. PMID: 36509249 Free PMC article.
-
Effects of passive and active leg movements to interrupt sitting in mild hypercapnia on cardiovascular function in healthy adults.J Appl Physiol (1985). 2022 Mar 1;132(3):874-887. doi: 10.1152/japplphysiol.00799.2021. Epub 2022 Feb 17. J Appl Physiol (1985). 2022. PMID: 35175102 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Miscellaneous
