Inability of Diaphragm Ultrasound to Predict Extubation Failure: A Multicenter Study

Chest. 2019 Jun;155(6):1131-1139. doi: 10.1016/j.chest.2019.03.004. Epub 2019 Mar 23.

Abstract

Background: Diaphragmatic dysfunction may promote weaning difficulties in patients who are mechanically ventilated.

Objective: The goal of this study was to assess whether diaphragm dysfunction detected by ultrasound prior to extubation could predict extubation failure in the ICU.

Methods: This multicenter prospective study included patients at high risk of reintubation: those aged > 65 years, with underlying cardiac or respiratory disease, or intubated > 7 days. All patients had successfully undergone a spontaneous breathing trial. Diaphragmatic function was assessed by ultrasound prior to extubation while breathing spontaneously on a T-piece. Bilateral diaphragmatic excursion and apposition thickening fraction were measured, and diaphragmatic dysfunction was defined as excursion < 10 mm or thickening < 30%. Cough strength was clinically assessed by physiotherapists. Extubation failure was defined as reintubation or death within the 7 days following extubation.

Results: Over a 20-month period, 191 at-risk patients were studied. Among them, 33 (17%) were considered extubation failures. The proportion of patients with diaphragmatic dysfunction was similar between those whose extubation succeeded and those whose extubation failed: 46% vs 51% using excursion (P = .55), and 71% vs 68% using thickening (P = .73), respectively. Values of excursion and thickening did not differ between the success and the failure groups: at right, excursion was 14 ± 7 mm vs 11 ± 8 (P = .13), and thickening was 29 ± 29% vs 38 ± 48% (P = .83), respectively. Extubation failure rates were 7%, 22%, and 46% in patients with effective, moderate, and ineffective cough (P < .01). Ineffective cough was the only variable independently associated with extubation failure.

Conclusions: Diaphragmatic dysfunction assessed by ultrasound was not associated with an increased risk of extubation failure.

Keywords: diaphragm; ultrasound; weaning.

Publication types

  • Multicenter Study
  • Observational Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Aged
  • Airway Extubation* / adverse effects
  • Airway Extubation* / methods
  • Airway Extubation* / mortality
  • Cough / etiology
  • Cough / physiopathology
  • Diaphragm* / diagnostic imaging
  • Diaphragm* / physiopathology
  • Female
  • Humans
  • Intubation, Intratracheal / methods
  • Male
  • Prospective Studies
  • Retreatment / methods
  • Retreatment / statistics & numerical data
  • Risk Assessment
  • Ultrasonography / methods*
  • Ventilator Weaning / methods*