Advancing performance evaluation standards for household water treatment technologies

J Water Health. 2019 Apr;17(2):266-273. doi: 10.2166/wh.2018.266.

Abstract

Diarrheal illnesses and fatalities continue to be major issues in many regions throughout the world. Household water treatment (HWT) technologies (including both point-of-use (POU) and point-of-entry (POE) treatment solutions) have been shown as able to deliver safe water in many low-income communities. However, as shown herein, there are important inconsistencies in protocols employed for validating performance of HWTs. The WHO does not stipulate influent concentration as a parameter that could influence removal efficacy, nor does it indicate an influent concentration range that should be used during technology evaluations. A correlation between influent concentration and removal is evidenced herein (R2 = 0.88) with higher influent concentrations resulting in higher log-removal values (LRVs). The absence of a recommended standard influent concentration of bacteria (as well as for viruses and protozoa) could have negative consequences in intervention efforts. Recommendations are provided that regulatory bodies should specify an influent concentration range for testing and verification of HWT technologies.

MeSH terms

  • Bacteria
  • Diarrhea
  • Housing
  • Humans
  • Viruses
  • Water
  • Water Microbiology*
  • Water Purification / methods
  • Water Purification / standards*

Substances

  • Water