A prospective cohort study comparing expulsion after postplacental insertion: the levonorgestrel versus the copper intrauterine device

Contraception. 2019 Aug;100(2):101-105. doi: 10.1016/j.contraception.2019.04.011. Epub 2019 May 17.

Abstract

Objectives: To compare the expulsion rate at 6 months after postplacental insertion by intrauterine device (IUD) type.

Study design: This prospective cohort included participants with a postplacental IUD inserted after vaginal or cesarean delivery, aged 18-45 and ≥24 weeks' gestation. Study enrollment took place after IUD selection and insertion. Participants returned for a postpartum visit and received a short message service survey regarding IUD expulsion, removal, vaginal bleeding and breastfeeding weekly from weeks 0 to 5 and on weeks 12 and 24 postpartum. Multivariable logistic regression examined 6-month expulsion rate by IUD type adjusting for variables that differed between the groups at baseline and in the bivariate analyses.

Results: Of 114 participants, 75 (65.8%) chose a levonorgestrel 52-mg IUD and 39 (34.2%) chose a copper IUD; 58 (50.9%) had a vaginal delivery, and 56 (49.1%) had a cesarean delivery. Groups were similar except that copper IUD users had a higher median parity (3 vs. 2, p=.03) and a higher proportion of senior residents compared to junior residents had performed insertion (46.2% vs. 22.7%, p=.02). The expulsion rate at 6 months was similar between the levonorgestrel and copper groups (26.7% and 20.5%, respectively; p=.38). Multivariable logistic regression also demonstrated that the odds of expulsion did not differ by IUD type (adjusted odds ratio 0.98, 95% confidence interval 0.22-4.48).

Conclusion: The expulsion rate at 6 months after postplacental insertion did not differ between the levonorgestrel and copper IUD type.

Implications: Prior studies demonstrate a wide range of expulsion after postplacental insertion, and recent data suggest a higher expulsion rate for the levonorgestrel compared to the copper intrauterine device. However, many studies did not control for patient-level factors or delivery route. We found that when controlling for these confounding variables, the expulsion rate at 6 months postpartum did not differ by intrauterine device type.

Keywords: Copper (Cu); Expulsion; Intrauterine device (IUD); Levonorgestrel (LNG); Postplacental; Short message service (SMS).

Publication types

  • Comparative Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adult
  • Cesarean Section / statistics & numerical data
  • Contraceptive Agents, Female / administration & dosage
  • Contraceptive Agents, Female / adverse effects*
  • Female
  • Humans
  • Intrauterine Device Expulsion / etiology*
  • Intrauterine Device Expulsion / trends
  • Intrauterine Devices, Copper / adverse effects*
  • Levonorgestrel / administration & dosage
  • Levonorgestrel / adverse effects*
  • Logistic Models
  • Multivariate Analysis
  • New York City
  • Postnatal Care*
  • Pregnancy
  • Prospective Studies
  • Time Factors

Substances

  • Contraceptive Agents, Female
  • Levonorgestrel