Toward the characterisation of non-intentionally added substances migrating from polyester-polyurethane lacquers by comprehensive gas chromatography-mass spectrometry technologies

J Chromatogr A. 2019 Sep 13:1601:327-334. doi: 10.1016/j.chroma.2019.05.024. Epub 2019 May 17.

Abstract

Polyester-polyurethane lacquer, used to cover the inner surface of metallic food contact materials, may transfer non-intentionally added substances (NIAS) to the food. The identification of such a diversity of compounds, considered as migrating substances, requires taking advantage of complementary analytical platforms. Therefore, four types of gas chromatography-mass spectrometry (GCMS) couplings were investigated and compared for their abilities to identify migrating substances after acetonitrile extraction of two commercialised lacquers. In parallel, various ionisation sources, i.e. electron ionisation (EI) (70 eV and soft energies) and atmospheric-pressure chemical ionisation (APCI) as well as various mass analysers, i.e. quadrupole, time-of-flight (low and high resolution) and Orbitrap, were tested. Comparison of mass spectra with a commercial library for EI ionisation source led to the identification of two NIAS compounds, isophorone diisocyanate and 4,4'-diphenylmethane diisocyanate. Additionally, many cyclic oligoesters (four monomer units) were unambiguously identified according to supplier's declaration on starting materials used, primarily based on the molecular ion observed by APCI mode and characteristic fragment ions. High resolution mass analysers also enhanced confidence level in such NIAS identification. One- and two-dimensional GC were also investigated for separation assessment. Although GC × GC did not reveal additional NIAS, its use provided a valuable mapping of oligomers according to monomers composition. These results were compared to our previously published LC-MS study, carried out on the same lacquer samples. This study shows that LC and GC, along with their related ionisation techniques and their own selectivity, are complementary approaches, revealing different classes of compounds covering a wide range of volatility and polarity.

Keywords: Chemical food safety; Food contact material; GC×GC; Identification; Oligomer; Untargeted approach.

MeSH terms

  • Atmospheric Pressure
  • Food Contamination / analysis
  • Food Packaging / standards*
  • Gas Chromatography-Mass Spectrometry*
  • Lacquer
  • Polyesters / chemistry*
  • Polyurethanes / chemistry*

Substances

  • Polyesters
  • Polyurethanes