Evaluation of the capability of the simulated dual energy X-ray absorptiometry-based two-dimensional finite element models for predicting vertebral failure loads
- PMID: 31147202
- DOI: 10.1016/j.medengphy.2019.05.007
Evaluation of the capability of the simulated dual energy X-ray absorptiometry-based two-dimensional finite element models for predicting vertebral failure loads
Abstract
Prediction of the vertebral failure load is of great importance for the prevention and early treatment of bone fracture. However, an efficient and effective method for accurately predicting the failure load of vertebral bones is still lacking. The aim of the present study was to evaluate the capability of the simulated dual energy X-ray absorptiometry (DXA)-based finite element (FE) model for predicting vertebral failure loads. Thirteen dissected spinal segments (T11/T12/L1) were scanned using a HR-pQCT scanner and then were mechanically tested until failure. The subject-specific three-dimensional (3D) and two-dimensional (2D) FE models of T12 were generated from the HR-pQCT scanner and the simulated DXA images, respectively. Additionally, the areal bone mineral density (aBMD) and areal bone mineral content (aBMC) of T12 were calculated. The failure loads predicted by the simulated DXA-based 2D FE models were more moderately correlated with the experimental failure loads (R2 = 0.66) than the aBMC (R2 = 0.61) and aBMD (R2 = 0.56). The 2D FE models were slightly outperformed by the HR-pQCT-based 3D FE models (R2 = 0.71). The present study demonstrated that the simulated DXA-based 2D FE model has better capability for predicting the vertebral failure loads than the densitometric measurements but is outperformed by the 3D FE model. The 2D FE model is more suitable for clinical use due to the low radiation dose and low cost, but it remains to be validated by further in vitro and in vivo studies.
Keywords: BMD; DXA; Finite element analysis; Prediction capability; Vertebral failure.
Copyright © 2019. Published by Elsevier Ltd.
Similar articles
-
Vertebral strength prediction from Bi-Planar dual energy x-ray absorptiometry under anterior compressive force using a finite element model: An in vitro study.J Mech Behav Biomed Mater. 2018 Nov;87:190-196. doi: 10.1016/j.jmbbm.2018.07.026. Epub 2018 Jul 17. J Mech Behav Biomed Mater. 2018. PMID: 30077078
-
QCT-based finite element models predict human vertebral strength in vitro significantly better than simulated DEXA.Osteoporos Int. 2012 Feb;23(2):563-72. doi: 10.1007/s00198-011-1568-3. Epub 2011 Feb 23. Osteoporos Int. 2012. PMID: 21344244
-
Distal skeletal tibia assessed by HR-pQCT is highly correlated with femoral and lumbar vertebra failure loads.J Biomech. 2017 Jul 5;59:43-49. doi: 10.1016/j.jbiomech.2017.05.011. Epub 2017 May 18. J Biomech. 2017. PMID: 28558915
-
Predicting bone strength from CT data: Clinical applications.Morphologie. 2019 Dec;103(343):180-186. doi: 10.1016/j.morpho.2019.09.007. Epub 2019 Oct 17. Morphologie. 2019. PMID: 31630964 Review.
-
Image-based finite-element modeling of the human femur.Comput Methods Biomech Biomed Engin. 2020 Nov;23(14):1138-1161. doi: 10.1080/10255842.2020.1789863. Epub 2020 Jul 12. Comput Methods Biomech Biomed Engin. 2020. PMID: 32657148 Review.
Cited by
-
Designing anisotropic porous bone scaffolds using a self-learning convolutional neural network model.Front Bioeng Biotechnol. 2022 Sep 27;10:973275. doi: 10.3389/fbioe.2022.973275. eCollection 2022. Front Bioeng Biotechnol. 2022. PMID: 36237207 Free PMC article.
-
Influence of the parameters of the convolutional neural network model in predicting the effective compressive modulus of porous structure.Front Bioeng Biotechnol. 2022 Sep 15;10:985688. doi: 10.3389/fbioe.2022.985688. eCollection 2022. Front Bioeng Biotechnol. 2022. PMID: 36185439 Free PMC article.
-
Beyond Bone Mineral Density: A New Dual X-Ray Absorptiometry Index of Bone Strength to Predict Fragility Fractures, the Bone Strain Index.Front Med (Lausanne). 2021 Jan 15;7:590139. doi: 10.3389/fmed.2020.590139. eCollection 2020. Front Med (Lausanne). 2021. PMID: 33521014 Free PMC article. Review.
-
A new finite element based parameter to predict bone fracture.PLoS One. 2019 Dec 5;14(12):e0225905. doi: 10.1371/journal.pone.0225905. eCollection 2019. PLoS One. 2019. PMID: 31805121 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources