Clinical and Angiographic Outcomes With a Novel Radiopaque Sirolimus-Eluting Bioresorbable Vascular Scaffold

Circ Cardiovasc Interv. 2019 Jun;12(6):e007283. doi: 10.1161/CIRCINTERVENTIONS.118.007283. Epub 2019 Jun 10.

Abstract

Background A novel bioresorbable scaffold, the sirolimus-eluting Fantom, incorporates a radiopaque polymer, struts with a thickness of 125 µm, and a crossing profile of 1.35 mm. The purpose of this study was to evaluate the 9-month angiographic and 12-month clinical outcomes of the FANTOM scaffold in a larger patient population. Methods and Results The FANTOM II study (Safety & Performance Study of the Fantom Sirolimus-Eluting Bioresorbable Coronary Scaffold - First Report on Initial 24 Month Outcomes) was a prospective, multicenter trial which enrolled 240 patients with single de novo coronary stenosis with reference vessel diameter 2.5 to 3.5 mm diameter and lesion length ≤20 mm. Major adverse cardiac events through 12-month follow-up were assessed. Angiographic follow-up was performed in consecutive patient cohorts at 6 months (n=117) and 9 months (n=123). Acute delivery success, acute technical success, acute procedural success, and clinical procedural success rates as defined in the clinical protocol were 97.9% (235/240), 95.8% (230/240), 99.1% (228/230), and 99.6% (227/228), respectively. The mean in-stent late lumen loss at 6 months and 9 months were 0.25±0.40 mm and 0.33±0.36 mm, respectively, and in-segment binary restenosis occurred in 2.0% and 7.6% of patients, respectively. Major adverse cardiac events and target lesion failure through 12 months occurred in 4.2% of 240 patients; scaffold thrombosis developed in only one patient (0.4%). Conclusions The Fantom sirolimus-eluting bioresorbable coronary scaffold demonstrated favorable safety and effectiveness performance at 12-month follow-up. Longer-term follow-up is ongoing to examine the late outcomes with this novel device. Clinical Trial Registration URL: https://www.clinicaltrials.gov . Unique identifier: NCT02539966.

Keywords: coronary artery disease; coronary stenosis; drug-eluting stents; sirolimus; stent.

Publication types

  • Multicenter Study

MeSH terms

  • Absorbable Implants*
  • Aged
  • Angioplasty, Balloon, Coronary / adverse effects
  • Angioplasty, Balloon, Coronary / instrumentation*
  • Cardiovascular Agents / administration & dosage*
  • Cardiovascular Agents / adverse effects
  • Coated Materials, Biocompatible*
  • Coronary Angiography*
  • Coronary Restenosis / diagnostic imaging
  • Coronary Restenosis / etiology
  • Coronary Stenosis / diagnostic imaging
  • Coronary Stenosis / therapy*
  • Coronary Thrombosis / diagnostic imaging
  • Coronary Thrombosis / etiology
  • Female
  • Humans
  • Male
  • Middle Aged
  • Predictive Value of Tests
  • Prospective Studies
  • Prosthesis Design
  • Severity of Illness Index
  • Sirolimus / administration & dosage*
  • Sirolimus / adverse effects
  • Time Factors
  • Treatment Outcome

Substances

  • Cardiovascular Agents
  • Coated Materials, Biocompatible
  • Sirolimus

Associated data

  • ClinicalTrials.gov/NCT02539966