Differential response to vibration of three forms of scoliosis during axial cyclic loading: a finite element study

BMC Musculoskelet Disord. 2019 Aug 14;20(1):370. doi: 10.1186/s12891-019-2728-4.

Abstract

Background: Scoliosis is a serious disease that can affect all segments of society. Few studies have investigated the response to vibration of differing sinusoidal axial cyclic loading frequencies for different forms of scoliosis in the lumbar spine.

Methods: In this study, four finite element models, comprising a healthy spine, Lenke-A, Lenke-B and Lenke-C scoliosis of the lumbar S1-L1 region were developed. Modal analysis extracted resonant frequencies of the FE models with an upper body mass of 40 kg and 400 N preload. A transient dynamic analysis was performed to obtain the response to vibration of models under a sinusoidal axial loading of ± 40N at frequencies of 3, 5, 7, 9, 11 and 13 Hz using an upper body mass of 40 kg and 400 N preload.

Results: The first-order resonant frequencies of healthy, Lenke-A, Lenke-B and Lenke-C spines were 9.2, 3.9, 4.6 and 5.7 Hz, respectively. A Lenke-A lumbar spine was more likely to deform at a lower vibration frequency and Lenke-C deformed more easily at a higher vibration frequency. Furthermore, the vibration amplitude in the Y-direction (left-right) was greatest and least in the Z-direction (top-bottom). The frequency of cyclic loading closest to the resonant frequency resulted in a maximum value of peak-to-peak vibrational displacement. Furthermore, the vibrational amplitudes in patients with scoliosis were larger than they were in healthy subjects. In addition, axial displacement of the vertebrae in the healthy spine changed steadily whereas fluctuations in the scoliotic vertebrae in scoliosis patients were greater than that of other vertebrae.

Conclusions: Different forms of scoliosis may have different vibrational characteristics, the scoliotic vertebrae being the weak link in scoliosis under loading condition of whole body vibration. Scoliosis was more sensitive to this form of vibration. Where the frequency of axial cyclic vibrational loading of the lumbar spine was closer to its resonant frequency, the vibrational amplitude was larger. These results suggest that vibration will exacerbate the degree of scoliosis and so such patients should reduce their exposure to vibration. Clinical treatment should pay attention to the scoliotic vertebrae and reduce their vibration. These findings may assist in the clinical prevention and treatment of scoliosis.

Keywords: Axial cyclic vibrational frequency; Dynamic response; FE model; Scoliosis.

Publication types

  • Validation Study

MeSH terms

  • Biomechanical Phenomena
  • Computer Simulation
  • Finite Element Analysis
  • Healthy Volunteers
  • Humans
  • Lumbar Vertebrae / physiopathology*
  • Male
  • Models, Biological*
  • Physical Therapy Modalities
  • Sacrum / physiopathology*
  • Scoliosis / physiopathology*
  • Scoliosis / therapy
  • Stress, Mechanical
  • Vibration / adverse effects*
  • Weight-Bearing / physiology