Objective: The objective of this study was to analyze if the addition of simple cardiac scan in cases with increased nuchal translucency (NT) and/or abnormal ductus venosus (DV) blood flow, and/or tricuspid regurgitation (TCR) can improve detection of congenital heart defects (CHD) in chromosomally normal fetuses without non-cardiac defects at 11-13 + 6 gestational weeks in a population of singleton pregnancies.
Methods: During the 10 years period, all singleton pregnancies at 11-13 + 6 weeks were routinely scanned for NT, DV blood flow and TCR assessment and, if a single of these parameters was abnormal, simple cardiac scan with 2D gray scale and color and/or directional power Doppler in 4-chamber (4-CV) and 3 vessel and trachea views (3VTV) was performed.
Results: The sensitivity and specificity of NT ≥ 95th + DV R/A a-wave + TCR in detecting CHD were 77% and 97%, respectively, and of simple cardiac scan, 67% and 98%, respectively. Area under the curve of receiver operating characteristic curve of NT ≥ 95th + DV R/A a-wave + TCR was 0.838, and of NT ≥ 95th + DV R/A a-wave + TCR + simple cardiac scan was 0.915.
Conclusions: In chromosomally normal fetuses without non-cardiac anomalies, addition of simple cardiac scan to the combined first trimester screening parameters improves detection of major CHD during first trimester.
Keywords: cardiac scan; congenital heart defect; ductus venosus; nuchal translucency thickness; tricuspid regurgitation.
© 2019 Wiley Periodicals, Inc.