Graphene Oxide/Polyethylene Glycol-Stick for Thin Film Microextraction of β-Blockers from Human Oral Fluid by Liquid Chromatography-Tandem Mass Spectrometry

Molecules. 2019 Oct 11;24(20):3664. doi: 10.3390/molecules24203664.

Abstract

A wooden stick coated with a novel graphene-based nanocomposite (Graphene oxide/polyethylene glycol (GO/PEG)) is introduced and investigated for its efficacy in solid phase microextraction techniques. The GO/PEG-stick was prepared and subsequently applied for the extraction of β-blockers, acebutolol, and metoprolol in human oral fluid samples, which were subsequently detected by liquid chromatography tandem mass spectrometry (LC-MS/MS). Experimental parameters affecting the extraction protocol including sample pH, extraction time, desorption time, appropriate desorption solvent, and salt addition were optimized. Method validation for the detection from oral fluid samples was performed following FDA (Food and Drug Administration) guidelines on bioanalytical method validation. Calibration curves ranging from 5.0 to 2000 nmol L-1 for acebutolol and 25.0 to 2000 nmol L-1 for metoprolol were used. The values for the coefficient of determination (R2) were found to be 0.998 and 0.996 (n = 3) for acebutolol and metoprolol, respectively. The recovery of analytes during extraction was 80.0% for acebutolol and 62.0% for metoprolol, respectively. The limit of detections (LODs) were 1.25, 8.00 nmol L-1 for acebutolol and metoprolol and the lower limit of quantifications (LLOQ) were 5.00 nmol L-1 for acebutolol and 25.0 nmol L-1 for metoprolol. Validation experiments conducted with quality control (QC) samples demonstrated method accuracy between 80.0% to 97.0% for acebutolol and from 95.0% to 109.0% for metoprolol. The inter-day precision for QC samples ranged from 3.6% to 12.9% for acebutolol and 9.5% to 11.3% for metoprolol. Additionally, the GO/PEG-stick was demonstrated to be reusable, with the same stick observed to be viable for more than 10 extractions from oral fluid samples.

Keywords: LC-MS/MS; graphene oxide/polyethylene glycol; oral fluid; wooden stick; β-blocker.

MeSH terms

  • Acebutolol / chemistry
  • Acebutolol / isolation & purification*
  • Adrenergic beta-Antagonists / chemistry
  • Adrenergic beta-Antagonists / isolation & purification*
  • Body Fluids / chemistry
  • Chromatography, Liquid
  • Graphite / chemistry
  • Humans
  • Limit of Detection
  • Metoprolol / chemistry
  • Metoprolol / isolation & purification*
  • Mouth / chemistry
  • Nanocomposites / chemistry
  • Polyethylene Glycols / chemistry
  • Solid Phase Microextraction / methods*
  • Tandem Mass Spectrometry

Substances

  • Adrenergic beta-Antagonists
  • graphene oxide
  • Polyethylene Glycols
  • Acebutolol
  • Graphite
  • Metoprolol