Comparison of Excimer Laser Versus Femtosecond Laser Assisted Trephination in Penetrating Keratoplasty: A Retrospective Study

Adv Ther. 2019 Dec;36(12):3471-3482. doi: 10.1007/s12325-019-01120-3. Epub 2019 Oct 24.

Abstract

Introduction: To compare the impact of non-mechanical excimer-assisted (EXCIMER) and femtosecond laser-assisted (FEMTO) trephination on outcomes after penetrating keratoplasty (PK).

Methods: In this retrospective study, 68 eyes from 23 females and 45 males (mean age at time of surgery, 53.3 ± 19.8 years) were included. Inclusion criteria were one surgeon (BS), primary central PK, Fuchs' dystrophy (FUCHS) or keratoconus (KC), no previous intraocular surgery, graft oversize 0.1 mm and 16-bite double running suture. Trephination was performed using a manually guided 193-nm Zeiss Meditec MEL70 excimer laser (EXCIMER group: 18 FUCHS, 17 KC) or 60-kHz IntraLase™ femtosecond laser (FEMTO group: 16 FUCHS, 17 KC). Subjective refractometry (trial glasses) and corneal topography analysis (Pentacam HR; Casia SS-1000 AS-OCT; TMS-5) were performed preoperatively, before removal of the first suture (11.4 ± 1.9 months) and after removal of the second suture (22.6 ± 3.8 months).

Results: Before suture removal, mean refractive/AS-OCT topographic astigmatism did not differ significantly between EXCIMER and FEMTO. After suture removal, mean refractive/Pentacam/AS-OCT topographic astigmatism was significantly higher in the FEMTO (6.2 ± 2.9 D/7.1 ± 3.2 D/7.4 ± 3.3 D) than in the EXCIMER patients (4.3 ± 3.0 D/4.4 ± 3.1 D/4.0 ± 2.9 D) (p ≤ 0.005). Mean corrected distance visual acuity increased from 0.22 and 0.23 preoperatively to 0.55 and 0.53 before or 0.7 and 0.6 after suture removal in the EXCIMER and FEMTO groups, respectively. Differences between EXCIMER and FEMTO were only pronounced in the KC subgroup.

Conclusion: Non-mechanical EXCIMER trephination seems to have advantages regarding postoperative corneal astigmatism and visual acuity compared with FEMTO trephination, especially in KC. A bigger sample size and longer follow-up are needed to evaluate the long-term impact of EXCIMER and FEMTO trephination on postoperative topographic and visual outcomes.

Keywords: Astigmatism; Excimer; Femtosecond; Laser; Ophthalmology; Penetrating keratoplasty; Visual acuity.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adult
  • Aged
  • Astigmatism
  • Corneal Topography
  • Female
  • Fuchs' Endothelial Dystrophy / surgery
  • Humans
  • Keratoconus / surgery
  • Keratoplasty, Penetrating / instrumentation*
  • Laser Therapy / adverse effects
  • Laser Therapy / instrumentation*
  • Lasers, Excimer / therapeutic use
  • Male
  • Middle Aged
  • Postoperative Period
  • Retrospective Studies
  • Visual Acuity

Associated data

  • figshare/10.6084/m9.figshare.9929915