A European inter-laboratory trial to evaluate the performance of three serological methods for diagnosis of Mycoplasma bovis infection in cattle using latent class analysis

BMC Vet Res. 2019 Oct 25;15(1):369. doi: 10.1186/s12917-019-2117-0.

Abstract

Background: Mycoplasma bovis (M. bovis) is an emerging bovine pathogen, leading to significant economic losses in the livestock industry worldwide. Infection can result in a variety of clinical signs, such as arthritis, pneumonia, mastitis and keratoconjunctivitis, none of which are M. bovis-specific. Laboratory diagnosis is therefore important. Serological tests to detect M. bovis antibodies is considered an effective indicator of infection in a herd and often used as a herd test. Combined with clinical judgement, it can also be used to implement control strategies and/or to estimate the disease prevalence within a country. However, due to lack of harmonisation of approaches to testing, and serological tests used by different laboratories, comparisons of prevalence data between countries is often difficult. A network of researchers from six European countries designed and participated in an inter-laboratory trial, with the aim of evaluating the sensitivity (Se) and specificity (Sp) of two commercially available ELISA tests (ID Screen® ELISA (IDvet) and BIO K302 ELISA (BIO-X Diagnostics)) for diagnosis of M. bovis infection. Each laboratory received a blinded panel of bovine sera and tested independently, according to manufacturer's instructions. Western blot analyses (WB) performed by one of the participating laboratories was used as a third diagnostic test in the statistical evaluation of Se and Sp values using latent class analysis.

Results: The Se of WB, the ID Screen® ELISA and the BIO K302 ELISA were determined to be 91.8, 93.5 and 49.1% respectively, and corresponding Sp of the three tests were 99.6, 98.6 and 89.6%, respectively.

Conclusions: The present study is, to our knowledge, the first to present an inter-laboratory comparison of the BIO K302 ELISA and the ID Screen® ELISA. Based on our results, the ID Screen® ELISA showed high consistency with WB and performed with higher precision and accuracy than the BIO K302 ELISA.

Keywords: ELISA; Inter-laboratory trial; Latent class analysis; Mycoplasma bovis cattle; Western blot.

Publication types

  • Evaluation Study

MeSH terms

  • Animals
  • Blotting, Western / veterinary
  • Cattle
  • Cattle Diseases / blood
  • Cattle Diseases / diagnosis*
  • Enzyme-Linked Immunosorbent Assay / methods
  • Enzyme-Linked Immunosorbent Assay / veterinary*
  • Latent Class Analysis
  • Mycoplasma Infections / blood
  • Mycoplasma Infections / diagnosis
  • Mycoplasma Infections / veterinary*
  • Mycoplasma bovis / immunology
  • Sensitivity and Specificity
  • Serologic Tests / veterinary