Purpose: Diffusion tensor imaging (DTI) is increasingly being used in magnetic resonance neurography (MRN). The purpose of this study was to determine the interreader and test-retest reliability of peripheral nerve DTI in MRN with focus on the sciatic nerve.
Methods: In this prospective study 27 healthy volunteers each underwent 3 scans of a short DTI protocol on separate days consisting of a T2-weighted turbo spin-echo and single-shot DTI sequence of the sciatic nerve of the dominant leg. The DTI parameters fractional anisotropy (FA), mean diffusivity (MD), axial diffusivity (AD), and radial diffusivity (RD) were obtained after manual nerve segmentation by two independent readers. Intraclass correlation coefficients (ICC), standard error of measurement (SEM), and Bland-Altman plots were calculated as measures for both interreader and test-retest agreement for all readout parameters.
Results: The mean ± standard deviation was 0.507 ± 0.05 for FA, 1308.5 ± 162.4 × 10-6 mm2/s for MD, 905.6 ± 145.4 ×10-6 mm2/s for RD and 2114.1 ± 219.2 × 10-6 mm2/s for AD. The SEM for FA was 0.02 for interreader and test-retest agreement, the SEM for MD, RD, and AD ranged between 46.2 × 10-6 mm2/s (RD) and 70.1 × 10-6 mm2/s (AD) for interreader reliability and between 45.9 × 10-6 mm2/s (RD) and 70.1 × 10-6 mm2/s (AD) for test-retest reliability. The ICC for interreader reliability of DTI parameters ranged between 0.81 and 0.92 and ICC for test-retest reliability between 0.76 and 0.91.
Conclusion: Peripheral nerve DTI of the sciatic nerve is reliable and reproducible. The measures presented here may serve as first orientation values of measurement accuracy when interpreting parameters of sciatic nerve DTI.
Keywords: Diffusion tensor imaging; Magnetic resonance imaging; Peripheral nervous system; Reference values; Reproducibility of results.
Similar articles
-
Reliability and reproducibility of sciatic nerve magnetization transfer imaging and T2 relaxometry.Eur Radiol. 2021 Dec;31(12):9120-9130. doi: 10.1007/s00330-021-08072-9. Epub 2021 Jun 9. Eur Radiol. 2021. PMID: 34104997 Free PMC article.
-
Diffusion tensor imaging of the sciatic nerve in Charcot-Marie-Tooth disease type I patients: a prospective case-control study.Eur Radiol. 2019 Jun;29(6):3241-3252. doi: 10.1007/s00330-018-5958-1. Epub 2019 Jan 11. Eur Radiol. 2019. PMID: 30635758
-
Peripheral nerve diffusion tensor imaging is reliable and reproducible.J Magn Reson Imaging. 2016 Apr;43(4):962-9. doi: 10.1002/jmri.25056. Epub 2015 Sep 23. J Magn Reson Imaging. 2016. PMID: 26397723
-
The role of diffusion tensor imaging and fractional anisotropy in the evaluation of patients with idiopathic normal pressure hydrocephalus: a literature review.Neurosurg Focus. 2016 Sep;41(3):E12. doi: 10.3171/2016.6.FOCUS16192. Neurosurg Focus. 2016. PMID: 27581308 Review.
-
Diffusion tensor imaging of optic neuropathies: a narrative review.Quant Imaging Med Surg. 2024 Jan 3;14(1):1086-1107. doi: 10.21037/qims-23-779. Epub 2024 Jan 2. Quant Imaging Med Surg. 2024. PMID: 38223128 Free PMC article. Review.
Cited by
-
Feasibility of in vivo multi-parametric quantitative magnetic resonance imaging of the healthy sciatic nerve with a unified signal readout protocol.Sci Rep. 2023 Apr 21;13(1):6565. doi: 10.1038/s41598-023-33618-w. Sci Rep. 2023. PMID: 37085693 Free PMC article.
-
Quantitative MR Neurography in Multifocal Motor Neuropathy and Amyotrophic Lateral Sclerosis.Diagnostics (Basel). 2023 Mar 25;13(7):1237. doi: 10.3390/diagnostics13071237. Diagnostics (Basel). 2023. PMID: 37046455 Free PMC article.
-
Sciatic nerve fractional anisotropy and neurofilament light chain protein are related to sensorimotor deficit of the upper and lower limbs in patients with type 2 diabetes.Front Endocrinol (Lausanne). 2023 Mar 14;14:1046690. doi: 10.3389/fendo.2023.1046690. eCollection 2023. Front Endocrinol (Lausanne). 2023. PMID: 37008917 Free PMC article.
-
Quantitative MR-Neurography at 3.0T: Inter-Scanner Reproducibility.Front Neurosci. 2022 Feb 16;16:817316. doi: 10.3389/fnins.2022.817316. eCollection 2022. Front Neurosci. 2022. PMID: 35250457 Free PMC article.
-
Reliability and reproducibility of sciatic nerve magnetization transfer imaging and T2 relaxometry.Eur Radiol. 2021 Dec;31(12):9120-9130. doi: 10.1007/s00330-021-08072-9. Epub 2021 Jun 9. Eur Radiol. 2021. PMID: 34104997 Free PMC article.
References
-
- Hagmann P, Jonasson L, Maeder P, Thiran JP, Wedeen VJ, Meuli R. Understanding diffusion MR imaging techniques: from scalar diffusion-weighted imaging to diffusion tensor imaging and beyond. Radiographics. 2006;26(Suppl 1):S205–23. - DOI
-
- Kronlage M, Pitarokoili K, Schwarz D, Godel T, Heiland S, Yoon MS, Bendszus M, Bäumer P. Diffusion tensor imaging in chronic inflammatory demyelinating polyneuropathy: diagnostic accuracy and correlation with electrophysiology. Invest Radiol. 2017;52:701–7. - DOI
-
- Vaeggemose M, Pham M, Ringgaard S, Tankisi H, Ejskjaer N, Heiland S, Poulsen PL, Andersen H. Magnetic resonance neurography visualizes abnormalities in sciatic and tibial nerves in patients with type 1 diabetes and neuropathy. Diabetes. 2017;66:1779–88. https://doi.org/10.2337/db16-1049 - DOI - PubMed - PMC
MeSH terms
LinkOut - more resources
Full Text Sources
Miscellaneous