Evaluation of a Hot Print System for the development of latent fingermarks on thermal paper: A pseudo-operational trial

Sci Justice. 2020 Jan;60(1):72-78. doi: 10.1016/j.scijus.2019.08.003. Epub 2019 Aug 12.

Abstract

Enhancement of latent fingermarks on thermal paper poses a number of problems when using traditional methods used for porous substrates due to blackening of the thermal layer as a result of polar solvents present within the reagents and high temperatures oxidising the acid/dye complex. Thus, methods which prevent such reactions are favoured for the development of latent prints on said substrates. A comparative pseudo-operational trial using UV, Hot Print System (HPS), ninhydrin and ThermaNIN was performed on 1000 thermal paper substrates gathered from various sources. The results indicated that the most effective method was an acetone pre-wash followed by ninhydrin. The sequence of HPS-ninhydrin was similarly effective when compared to ninhydrin as a sole technique. ThermaNIN produced fewer marks than ninhydrin but was superior to HPS. Whilst the HPS developed some fingermarks, there was only a very small number of marks uniquely developed by it.

Publication types

  • Comparative Study
  • Evaluation Study

MeSH terms

  • Dermatoglyphics*
  • Hot Temperature
  • Humans
  • Image Enhancement / methods*
  • Indicators and Reagents
  • Ninhydrin / analogs & derivatives
  • Paper
  • Porosity
  • Ultraviolet Rays

Substances

  • Indicators and Reagents
  • Ninhydrin