Background: Needleless connectors (NCs) were introduced to reduce health care work needlestick injuries (NSIs). If not decontaminated prior to use, NCs can be a portal for patient blood stream infections. The optimal disinfectant, and its application duration, for NC decontamination has not been empirically established.
Methods: Factorial design randomized controlled trial comparing 70% isopropyl alcohol (IPA) and 2% chlorhexidine gluconate (CHG) in 70% IPA for 5, 10, or 15 seconds, in adult medical patients with peripheral intravenous catheters.
Results: At baseline, 153 of 300 NCs (51%) grew microorganisms commonly found on the skin. Decontamination was successful in 150/153 (98%). There was no significant difference in decontamination between 70% IPA or 2% CHG in 70% IPA (P = .62), or decontamination for 5, 10, or 15 seconds (P = .21).
Conclusions: There was no difference in the effectiveness of 70% IPA and 2% CHG in 70% IPA for NC decontamination for peripheral intravenous catheters in the clinical environment. Successful decontamination was not different for applications of 5, 10, and 15 seconds; 15 seconds did not always remove all microorganisms. Factors such as cost, feasibility of compliance, and low risk of allergy support 5 seconds decontamination with 70% IPA as an acceptable approach.
Keywords: Blood stream infection; Microbiology.
Crown Copyright © 2019. Published by Elsevier Inc. All rights reserved.
Similar articles
-
A mixed-methods evaluation on the efficacy and perceptions of needleless connector disinfectants.Infect Control Hosp Epidemiol. 2023 Feb;44(2):230-233. doi: 10.1017/ice.2022.72. Epub 2022 Apr 7. Infect Control Hosp Epidemiol. 2023. PMID: 35387702 Free PMC article.
-
Needleless connector decontamination for prevention of central venous access device infection: A pilot randomized controlled trial.Am J Infect Control. 2021 Feb;49(2):269-273. doi: 10.1016/j.ajic.2020.07.026. Epub 2020 Jul 29. Am J Infect Control. 2021. PMID: 32735809 Clinical Trial.
-
An in vitro evaluation of disinfection protocols used for needleless connectors of central venous catheters.Lett Appl Microbiol. 2013 Oct;57(4):282-7. doi: 10.1111/lam.12108. Epub 2013 Jun 7. Lett Appl Microbiol. 2013. PMID: 23710651 Free PMC article.
-
Skin antisepsis: using 2% chlorhexidine gluconate in 70% isopropyl alcohol.Br J Nurs. 2007 Dec 13-2008 Jan 9;16(22):1390, 1392-4. doi: 10.12968/bjon.2007.16.22.27769. Br J Nurs. 2007. PMID: 18361387 Review.
-
The effects of needleless connectors on catheter-related bloodstream infections.Am J Infect Control. 2011 May;39(4):277-83. doi: 10.1016/j.ajic.2010.07.011. Epub 2011 Jan 22. Am J Infect Control. 2011. PMID: 21256629 Review.
Cited by
-
A Low-Cost Protocol Using the Adjunctive Action of Povidone-Iodine Irrigations and Sodium Hypochlorite Rinsing Solution in Step 2 of Periodontal Therapy for Patients with Stage III-IV Periodontitis: A Single-Blind, Randomized Controlled Trial.Dent J (Basel). 2024 May 15;12(5):144. doi: 10.3390/dj12050144. Dent J (Basel). 2024. PMID: 38786542 Free PMC article.
-
Disinfection of needleless connectors for catheters in one second using a hand-held UV device.Am J Infect Control. 2024 Aug;52(8):915-918. doi: 10.1016/j.ajic.2024.03.017. Epub 2024 Apr 22. Am J Infect Control. 2024. PMID: 38657905
-
Factors associated with the disinfection of devices attached to peripheral intravenous catheters performed by the nursing team in pediatric units.J Infect Prev. 2024 May;25(3):66-72. doi: 10.1177/17571774241231675. Epub 2024 Feb 4. J Infect Prev. 2024. PMID: 38584710
-
Compliance with central venous catheter infection prevention practices after intervention with simulation.Rev Bras Enferm. 2023 Oct 9;76(4):e20220574. doi: 10.1590/0034-7167-2022-0574. eCollection 2023. Rev Bras Enferm. 2023. PMID: 37820143 Free PMC article.
-
A mixed-methods evaluation on the efficacy and perceptions of needleless connector disinfectants.Infect Control Hosp Epidemiol. 2023 Feb;44(2):230-233. doi: 10.1017/ice.2022.72. Epub 2022 Apr 7. Infect Control Hosp Epidemiol. 2023. PMID: 35387702 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources