Levothyroxine Absorption Test to Differentiate Pseudomalabsorption from True Malabsorption

Eur Thyroid J. 2020 Jan;9(1):19-24. doi: 10.1159/000504218. Epub 2019 Nov 20.

Abstract

Background: The levothyroxine absorption test for evaluation of pseudomalabsorption in patients with primary hypothyroid is not standardised. An individual in whom a workup for malabsorption is warranted remains undefined.

Methods: Twenty-five euthyroid, 25 newly diagnosed hypothyroid, 25 treated hypothyroid with normalised TSH, and 25 hypothyroid subjects with elevated TSH despite adequate dose of levothyroxine for more than 6 months, and 10 euthyroid subjects with true malabsorption were administered levothyroxine (10 μg/kg or maximum 600 μg) to study its absorption profile by measuring free T4 level at hourly intervals for 5 h. Results : Free T4 peaked at 3 h with marginal insignificant decline at 4 h in all groups. The increments of free T4 (between baseline and 3 h) of the four groups (except malabsorption) were not statistically different. The mean increment of free T4 in true malabsorption was 0.39 ng/dL (95% CI: 0.29-0.52) and it was 0.78 ng/dL (95% CI: 0.73-0.85) (10.4 pmol/L) for other groups combined together. The cut off of free T4 increment at 3 h from baseline above 0.40 ng/dL had a sensitivity of 97% and specificity of 80% (AUC 0.904, p < 0.001) to exclude true malabsorption.

Conclusion: Subjects with elevated TSH on adequate dose of LT4 can be reliably diagnosed to be non-adherent to treatment with levothyroxine absorption test. The incremental value above 0.40 ng/dL (5.14 pmol/L) at 3 h may be useful to identify individuals where workup of malabsorption is unwarranted.

Keywords: Compliance; Levothyroxine absorption test; Primary hypothyroidism; Pseudomalabsorption.