Objectives: This study sought to examine clinical characteristics of procedural and long-term outcomes in patients undergoing catheter ablation (CA) of outflow tract ventricular arrhythmias (OT-VAs) over 16 years.
Background: CA is an effective treatment strategy for OT-VAs.
Methods: Patients undergoing CA for OT-VAs from 1999 to 2015 were divided into 3 periods: 1999 to 2004 (early), 2005 to 2010 (middle), and 2011 to 2015 (recent). Successful ablation site (right ventricular OT, aortic cusps/left ventricular OT, or coronary venous system/epicardium), VA morphology (right bundle branch block or left bundle branch block), and acute and clinical success rates were assessed.
Results: Six hundred eighty-two patients (336 female) were included (early: n = 97; middle: n = 204; recent: n = 381). Over time there was increase in use of irrigated ablation catheters and electroanatomic mapping, and more VAs were ablated from the aortic cusp/left ventricular OT or coronary venous system/epicardium (14% vs. 45% vs. 56%; p < 0.0001). Acute procedural success was achieved in 585 patients (86%) and was similar between groups (82% vs. 84% vs. 88%; p = 0.27). Clinical success was also similar between groups (86% vs. 87% vs. 88%; p = 0.94), but more patients in earlier periods required repeat ablation (18% vs. 17% vs. 9%; p = 0.02). Overall complication rate was 2% (similar between groups).
Conclusions: Over a 16-year period there was an increase in patients undergoing CA for OT-VTs, with more ablations performed at non-right ventricular outflow tract locations using electroanatomic mapping and irrigated-tip catheters. Over time, single procedure success has improved and complications have remained limited.
Keywords: catheter ablation; outflow tract; ventricular arrhythmia.
Copyright © 2020 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.