Intracardiac echocardiography use and outcomes after catheter ablation of ventricular tachycardia

J Comp Eff Res. 2020 Apr;9(5):375-385. doi: 10.2217/cer-2019-0156. Epub 2020 Mar 5.

Abstract

Aim: To compare outcomes among patients with implantable cardioverter defibrillator/cardiac resynchronization therapy-defibrillator undergoing outpatient ventricular tachycardia (VT) catheter ablation using intracardiac echocardiography (ICE) versus no ICE. Patients & methods: Patients were classified into ICE (n = 1143)/non-ICE (n = 1677) groups based on ICE procedure codes. Patients in each group were propensity matched on study covariates. Survival analyses were used to assess outcomes. To examine residual confounding, falsification outcomes were evaluated. Results: ICE patients had a 24% lower risk of all-cause readmissions, 24% lower risk of cardiovascular-related and 20% lower risk of VT-related readmissions compared with non-ICE patients. Falsification analyses for ICE use association were nonsignificant. Conclusion: Patients with implantable cardioverter defibrillator/cardiac resynchronization therapy-defibrillator undergoing VT ablation with ICE use had significantly lower likelihood of VT-related readmission.

Keywords: Medicare; catheter ablation; intracardiac echocardiography; observational study; real-word evidence; retrospective analysis; ventricular tachycardia.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Aged
  • Aged, 80 and over
  • Catheter Ablation / methods*
  • Defibrillators, Implantable*
  • Echocardiography / methods*
  • Female
  • Humans
  • Male
  • Tachycardia, Ventricular / diagnostic imaging*
  • Tachycardia, Ventricular / surgery*
  • Treatment Outcome