A novel endoscopic hand-suturing technique for defect closure after colorectal endoscopic submucosal dissection: a pilot study

Endoscopy. 2020 Sep;52(9):780-785. doi: 10.1055/a-1120-8533. Epub 2020 Mar 23.

Abstract

Background: This study aimed to demonstrate the feasibility of endoscopic hand-suturing (EHS) and attainability of sustained closure after colorectal endoscopic submucosal dissection (ESD).

Methods: EHS was defined as uninterrupted endoscopic suturing of the mucosal defect after colorectal ESD using an absorbable barbed suture and a through-the-scope needle holder. Following individual EHS training using an ex vivo porcine colonic model, two experienced endoscopists performed EHS. Repeat colonoscopy was performed on the third or fourth day after ESD to examine the EHS site. The primary end point was the complete EHS closure rate, and secondary end points were sustained closure and post-ESD bleeding rates.

Results: 11 lesions were included. Median size of the mucosal defect was 38 mm (range 25 - 55 mm) and the lesion characteristics were as follows: lower rectum/upper rectum/ascending colon/cecum = 3/3/2/3, and 0-IIa/0-Is + IIa/others = 5/4/2. EHS was not attempted in two patients owing to difficulty in colonoscope reinsertion after ESD and intraoperative perforation, respectively. EHS was performed for nine lesions, and the complete EHS closure rate was 73 %. Median procedure time for suturing was 56 minutes (range 30 - 120 minutes) and median number of stitches was 8 (range 6 - 12). Sustained closure and post-ESD bleeding rates were 64 % and 9 %, respectively.

Conclusions: EHS achieved complete and sustained closure in the colorectum. However, EHS is not currently clinically applicable given the long procedure time. Further modifications of the technique and devices are desirable.

MeSH terms

  • Animals
  • Colonoscopy
  • Colorectal Neoplasms* / surgery
  • Endoscopic Mucosal Resection* / adverse effects
  • Humans
  • Intestinal Mucosa / surgery
  • Pilot Projects
  • Sutures
  • Swine

Associated data

  • UMIN-CTR/UMIN000031512