Background: Area under expiratory flow-volume curve (AEX) is a useful spirometric tool in stratifying respiratory impairment. The AEX approximations based on isovolumic flows can be used with reasonable accuracy when AEX is unavailable. We assessed here pre- to post-bronchodilator (BD) variability of AEX4 as a functional assessment tool for lung disorders.
Methods: The BD response was assessed in 4330 subjects by changes in FEV1, FVC, and AEX4, which were derived from FVC, peak expiratory flow, and forced expiratory flow at 25%, 50%, and 75% FVC. Newly proposed BD response categories (negative, minimal, mild, moderate and marked) have been investigated in addition to standard criteria.
Results: Using standard BD criteria, 24% of subjects had a positive response. Using the new BD response categories, only 23% of subjects had a negative response; 45% minimal, 18% mild, 9% moderate, and 5% had a marked BD response. Mean percent change of the square root AEX4 was 0.3% and 14.3% in the standard BD-negative and BD-positive response groups, respectively. In the new BD response categories of negative, minimal, mild, moderate, and marked, mean percent change of square root AEX4 was - 8.2%, 2.9%, 9.2%, 15.0%, and 24.8%, respectively.
Conclusions: Mean pre- to post-BD variability of AEX4 was < 6% and stratified well between newly proposed categories of BD response (negative, minimal, mild, moderate and marked). We suggest that AEX4 (AEX) could become a useful measurement for stratifying dysfunction in obstructive lung disease and invite further investigation into indications for using bronchodilator agents or disease-modifying, anti-inflammatory therapies.
Keywords: Area under flow–volume curve; Bronchodilator response; Lung function; Lung volumes; Spirometry.