Hounsfield units value is a better predictor of pedicle screw loosening than the T-score of DXA in patients with lumbar degenerative diseases

Eur Spine J. 2020 May;29(5):1105-1111. doi: 10.1007/s00586-020-06386-8. Epub 2020 Mar 24.

Abstract

Purpose: To compare the performance of using Hounsfield units (HU) value derived from computed tomography and T-score of dual-energy X-ray absorptiometry (DXA) to predict pedicle screw loosening.

Methods: We reviewed 253 patients aged ≥ 50 years undergoing pedicle screw fixation for lumbar degenerative diseases (LDD). The evaluation of screw loosening: radiolucent zones of ≥ 1 mm thick in X-ray. The criterion for osteoporosis: the lowest T-score ≤ - 2.5. The average HU value of L1-L4 was used to represent lumbar bone mineral density (BMD). The area under receiver operating characteristics curve (AUC) was used to evaluate the performance of predicting screw loosening.

Results: One patient underwent reoperation for screw loosening at 9 months follow-up. At 12 months follow-up, the loosening rate was 30.6% (77/252) in the remaining 252 patients. Osteoporotic patients had higher loosening rate than non-osteoporotic patients (39.3% vs. 25.8%, P = 0.026). The T-score showed no significant difference between loosening group and non-loosening group (- 2.1 ± 1.5 vs. - 1.7 ± 1.6, P = 0.074), and so is the lowest lumbar BMD of DXA (0.83 ± 0.16 g/cm2 vs. 0.88 ± 0.19 g/cm2, P = 0.054). The HU value was lower in the loosening group (106.8 ± 34.4 vs. 129.8 ± 45.7, P < 0.001). The HU value (OR, 0.980; 95%CI 0.968-0.993; P = 0.002) was the independent influencing factor of screw loosening. The AUC of predicting screw loosening was 0.666 (P < 0.001) for HU value and 0.574 (P = 0.062) for T-score.

Conclusions: HU value is a better predictor of pedicle screw loosening than T-score of DXA in patients aged ≥ 50 years with LDD. We should not only focus on the DXA measurements when making surgical plans concerning lumbar fixation. These slides can be retrieved under Electronic Supplementary Material.

Keywords: Dual-energy X-ray absorptiometry; Hounsfield units; Lumbar degenerative diseases; Pedicle screw loosening; T-score.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Absorptiometry, Photon
  • Aged
  • Bone Density
  • Humans
  • Lumbar Vertebrae / diagnostic imaging
  • Lumbar Vertebrae / surgery
  • Osteoporosis / diagnostic imaging
  • Osteoporosis / surgery
  • Pedicle Screws*