Bone Mineral Densitometry Reporting: Pearls and Pitfalls
- PMID: 32309998
- DOI: 10.1177/0846537120919627
Bone Mineral Densitometry Reporting: Pearls and Pitfalls
Abstract
Dual-energy X-ray absorptiometry (DXA) is the method of choice for assessing bone mineral density (BMD). Unfortunately, the performance and interpretation of DXA can be challenging and errors are common. In fact, it has been reported that up to 90% of BMD reports contain at least 1 error. Errors can be the result of technique or interpretative in nature or both and can result in inappropriate diagnosis and management. In this article, we review the various types of pitfalls frequently encountered by physicians interpreting DXA studies. Being aware of these pitfalls will help readers recognize and avoid them when encountered in clinical practice.
Keywords: dual-energy X-ray absorptiometry; fractures; osteoporosis.
Similar articles
-
Common errors in dual-energy X-ray absorptiometry scans in imaging centers in Ecuador.Arch Osteoporos. 2020 Jan 2;15(1):6. doi: 10.1007/s11657-019-0673-3. Arch Osteoporos. 2020. PMID: 31897808
-
Dual-energy X-ray absorptiometry bone densitometry and pitfalls in the assessment of osteoporosis: a primer for the practicing clinician.Arch Osteoporos. 2020 Aug 24;15(1):135. doi: 10.1007/s11657-020-00808-2. Arch Osteoporos. 2020. PMID: 32833113
-
Erdheim-Chester disease: a pitfall in DXA measurements.Rheumatol Int. 2010 Jan;30(3):425-8. doi: 10.1007/s00296-009-1022-4. Epub 2009 Jul 4. Rheumatol Int. 2010. PMID: 19578853 No abstract available.
-
Operator-Related Errors and Pitfalls in Dual Energy X-Ray Absorptiometry: How to Recognize and Avoid Them.Acad Radiol. 2021 Sep;28(9):1272-1286. doi: 10.1016/j.acra.2020.07.028. Epub 2020 Aug 22. Acad Radiol. 2021. PMID: 32839098 Review.
-
Use of Trabecular Bone Score (TBS) as a Complementary Approach to Dual-energy X-ray Absorptiometry (DXA) for Fracture Risk Assessment in Clinical Practice.J Clin Densitom. 2017 Jul-Sep;20(3):334-345. doi: 10.1016/j.jocd.2017.06.019. Epub 2017 Jul 19. J Clin Densitom. 2017. PMID: 28734710 Review.
Cited by
-
Artificial High- and Low-density Materials in Bone Mineral Densitometry Using Dual-energy X-ray Absorptiometry: A GATE Monte Carlo Simulation of "Black-hole" Artifact.J Med Phys. 2024 Jul-Sep;49(3):433-440. doi: 10.4103/jmp.jmp_36_24. Epub 2024 Sep 21. J Med Phys. 2024. PMID: 39526158 Free PMC article.
-
Utility of iliac crest tetracycline-labelled bone biopsy in osteoporosis and metabolic bone disease: An evaluation of 95 cases over a period of 25 years.Bone Rep. 2023 Sep 24;19:101715. doi: 10.1016/j.bonr.2023.101715. eCollection 2023 Dec. Bone Rep. 2023. PMID: 37811524 Free PMC article.
-
Detecting whether L1 or other lumbar levels would be excluded from DXA bone mineral density analysis during opportunistic CT screening for osteoporosis using machine learning.Int J Comput Assist Radiol Surg. 2023 Dec;18(12):2261-2272. doi: 10.1007/s11548-023-02910-5. Epub 2023 May 23. Int J Comput Assist Radiol Surg. 2023. PMID: 37219803
-
BatchBMD as an Efficient and Accurate Dual-Energy X-ray Absorptiometry Report Generator.Diagnostics (Basel). 2021 Dec 20;11(12):2403. doi: 10.3390/diagnostics11122403. Diagnostics (Basel). 2021. PMID: 34943639 Free PMC article.
-
Longitudinal Changes of Circulating miRNAs During Bisphosphonate and Teriparatide Treatment in an Animal Model of Postmenopausal Osteoporosis.J Bone Miner Res. 2021 Jun;36(6):1131-1144. doi: 10.1002/jbmr.4276. Epub 2021 Mar 10. J Bone Miner Res. 2021. PMID: 33598975 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical