Potassium Bromate as Positive Assay Control for the Fpg-modified Comet Assay
- PMID: 32319518
- DOI: 10.1093/mutage/geaa011
Potassium Bromate as Positive Assay Control for the Fpg-modified Comet Assay
Abstract
The comet assay is a popular assay in biomonitoring studies. DNA strand breaks (or unspecific DNA lesions) are measured using the standard comet assay. Oxidative stress-generated DNA lesions can be measured by employing DNA repair enzymes to recognise oxidatively damaged DNA. Unfortunately, there has been a tendency to fail to report results from assay controls (or maybe even not to employ assay controls). We believe this might have been due to uncertainty as to what really constitutes a positive control. It should go without saying that a biomonitoring study cannot have a positive control group as it is unethical to expose healthy humans to DNA damaging (and thus potentially carcinogenic) agents. However, it is possible to include assay controls in the analysis (here meant as a cryopreserved sample of cells i.e. included in each experiment as a reference sample). In the present report we tested potassium bromate (KBrO3) as a positive comet assay control for the formamidopyrimidine DNA glycosylase (Fpg)-modified comet assay. Ten laboratories used the same procedure for treatment of monocytic THP-1 cells with KBrO3 (0.5, 1.5 and 4.5 mM for 1 h at 37°C) and subsequent cryopreservation. Results from one laboratory were excluded in the statistical analysis because of technical issues in the Fpg-modified comet assay. All other laboratories found a concentration-response relationship in cryopreserved samples (regression coefficients from 0.80 to 0.98), although with different slopes ranging from 1.25 to 11.9 Fpg-sensitive sites (%DNA in tail) per 1 mM KBrO3. Our results demonstrate that KBrO3 is a suitable positive comet assay control.
© The Author(s) 2020. Published by Oxford University Press on behalf of the UK Environmental Mutagen Society.All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Similar articles
-
Searching for assay controls for the Fpg- and hOGG1-modified comet assay.Mutagenesis. 2018 Feb 24;33(1):9-19. doi: 10.1093/mutage/gex015. Mutagenesis. 2018. PMID: 28992346 Review.
-
hOGG1 recognizes oxidative damage using the comet assay with greater specificity than FPG or ENDOIII.Mutagenesis. 2006 May;21(3):185-90. doi: 10.1093/mutage/gel019. Epub 2006 Apr 5. Mutagenesis. 2006. PMID: 16597659
-
An ECVAG inter-laboratory validation study of the comet assay: inter-laboratory and intra-laboratory variations of DNA strand breaks and FPG-sensitive sites in human mononuclear cells.Mutagenesis. 2013 May;28(3):279-86. doi: 10.1093/mutage/get001. Epub 2013 Feb 27. Mutagenesis. 2013. PMID: 23446176
-
Cryopreservation of human blood for alkaline and Fpg-modified comet assay.Toxicol Mech Methods. 2016;26(3):196-201. doi: 10.3109/15376516.2016.1144126. Epub 2016 Mar 16. Toxicol Mech Methods. 2016. PMID: 26982377
-
Technical recommendations to perform the alkaline standard and enzyme-modified comet assay in human biomonitoring studies.Mutat Res. 2019 Jul;843:24-32. doi: 10.1016/j.mrgentox.2019.04.007. Epub 2019 May 1. Mutat Res. 2019. PMID: 31421734 Review.
LinkOut - more resources
Full Text Sources