Direct measurement of atrioventricular valve regurgitant jets using 4D flow cardiovascular magnetic resonance is accurate and reliable for children with congenital heart disease: a retrospective cohort study

J Cardiovasc Magn Reson. 2020 May 14;22(1):33. doi: 10.1186/s12968-020-00612-4.

Abstract

Background: 3D-time resolved flow (4DF) cardiovascular magnetic resonance (CMR) with retrospective analysis of atrioventricular valve regurgitation (AVVR) allows for internal validation by multiple direct and indirect methods. Limited data exist on direct measurement of AVVR by 4DF CMR in pediatric congenital heart disease (CHD). We aimed to validate direct measurement of the AVVR jet as accurate and reliable compared to the volumetric method (clinical standard by 2D CMR) and as a superior method of internal validation than the annular inflow method.

Methods: We identified 44 consecutive patients with diverse CHD referred for evaluation of AVVR by CMR. 1.5 T or 3 T scanners, intravenous contrast, and a combination of parallel imaging and compressed sensing were used. Four methods of measuring AVVR volume (RVol) were used: volumetric method (VOL; the clinical standard) = stroke volume by 2D balanced steady-state free precession - semilunar valve forward flow (SLFF); annular inflow method (AIM) = atrioventricular valve forward flow [AVFF] - semilunar valve net flow (SLNF); and direct measurement (JET). AVFF was measured using static and retrospective valve tracking planes. SLFF, SLNF, AVFF, and JET were measured by 4DF phase contrast. Regurgitant fraction was calculated as [RVol/(RVol+SLNF)]× 100. Statistical methods included Spearman, Wilcoxon rank sum test/Student paired t-test, Bland Altman analysis, and intra-class coefficient (ICC), where appropriate.

Results: Regurgitant fraction by JET strongly correlated with the indirect methods (VOL and AIM) (ρ = 0.73-0.80, p < 0.001) and was similar to VOL with a median difference (interquartile range) of - 1.5% (- 8.3-7.2%; p = 0.624). VOL had weaker correlations with AIM and JET (ρ = 0.69-0.73, p < 0.001). AIM underestimated RF by 3.6-6.9% compared to VOL and JET, p < 0.03. Intra- and inter- observer reliability were excellent for all methods (ICC 0.94-0.99). The mean (±standard deviation) inter-observer difference for VOL was 2.4% (±5.1%), p < 0.05.

Conclusions: In a diverse cohort of pediatric CHD, measurement of AVVR using JET is accurate and reliable to VOL and is a superior method of internal validation compared to AIM. This study supports use of 4DF CMR for measurement of AVVR, obviating need for expert prospective prescription during image acquisition by 2D CMR.

Keywords: 4D flow; 4DF CMR; Atrioventricular valve regurgitation; Direct measurement of regurgitant jet; MRI; Pediatric CHD.

Publication types

  • Comparative Study
  • Validation Study
  • Video-Audio Media

MeSH terms

  • Adolescent
  • Age Factors
  • Child
  • Child, Preschool
  • Female
  • Heart Defects, Congenital / diagnostic imaging*
  • Heart Defects, Congenital / physiopathology
  • Heart Defects, Congenital / surgery
  • Hemodynamics*
  • Humans
  • Image Interpretation, Computer-Assisted*
  • Magnetic Resonance Imaging*
  • Male
  • Mitral Valve / diagnostic imaging*
  • Mitral Valve / physiopathology
  • Mitral Valve Insufficiency / diagnostic imaging*
  • Mitral Valve Insufficiency / physiopathology
  • Observer Variation
  • Predictive Value of Tests
  • Reproducibility of Results
  • Retrospective Studies
  • Tricuspid Valve / diagnostic imaging*
  • Tricuspid Valve / physiopathology
  • Tricuspid Valve Insufficiency / diagnostic imaging*
  • Tricuspid Valve Insufficiency / physiopathology
  • Young Adult