Intrarater reliability and validity of outcome measures in myotonic dystrophy type 1

Neurology. 2020 Jun 16;94(24):e2508-e2520. doi: 10.1212/WNL.0000000000009625. Epub 2020 May 26.

Abstract

Objective: To investigate intrarater reliability and concurrent and construct validity of muscle strength, balance, and functional mobility measures in individuals with noncongenital myotonic dystrophy type 1 (DM1).

Methods: Seventy-eight adults with noncongenital DM1 participated in visit 1, and 73 of the them participated in visit 2 separated by 1 to 2 weeks. The assessments consisted of muscle strength tests with handheld dynamometry (HHD) and stationary dynamometry in the lower limb. The balance tests consisted of the step test, Timed Up and Go test, feet-together stance, tandem stance, 1-leg stance, and modified Clinical Test of Sensory Integration and Balance on a balance platform. The functional mobility tests consisted of the 10-m walk test (10mWT) and 10-times Sit-to-Stand test.

Results: The HHD and stationary dynamometry had sufficient intrarater reliability for most muscle groups on a group (SEM% ≤15%) and individual (minimal detectable difference [MDD95%] ≤30%) level, but the HHD was most reliable. Stationary dynamometry measured a higher torque than HHD for all extensor muscles, but for single individuals, none of the devices were favored. Overall, intrarater reliability and validity were sufficient only for the dynamic balance tests, not the static balance tests. Both functional mobility tests were sufficiently reliable and valid, but the 10mWT was most reliable.

Conclusion: Overall, HHD is recommended as a reliable and valid tool for single individuals and for flexor muscles on a group level. For balance assessments, the dynamic balance tests are recommended as the most valid and reliable balance tests. Both functional mobility tests are recommended for valid and reliable outcomes, but the 10mWT was superior for reliability.

MeSH terms

  • Adult
  • Aged
  • Cohort Studies
  • Exercise Test
  • Female
  • Hand Strength
  • Humans
  • Lower Extremity / physiopathology
  • Male
  • Middle Aged
  • Mobility Limitation
  • Muscle Strength
  • Muscle Strength Dynamometer
  • Myotonic Dystrophy / physiopathology*
  • Myotonic Dystrophy / therapy
  • Observer Variation
  • Postural Balance
  • Reproducibility of Results
  • Treatment Outcome
  • Walk Test