. 2020 Jul;22(7):501-508.
doi: 10.1089/dia.2020.0236.

Estimation of Hemoglobin A1c from Continuous Glucose Monitoring Data in Individuals with Type 1 Diabetes: Is Time In Range All We Need?

Affiliations

Estimation of Hemoglobin A1c from Continuous Glucose Monitoring Data in Individuals with Type 1 Diabetes: Is Time In Range All We Need?

Chiara Fabris et al. Diabetes Technol Ther. 2020 Jul.

Abstract

Objective: To bridge the gap between laboratory-measured hemoglobin A1c (HbA1c) and continuous glucose monitoring (CGM)-derived time in target range (TIR), introducing TIR-driven estimated A1c (eA1c). Methods: Data from Protocol 1 (training data set) and Protocol 3 (testing data set) of the International Diabetes Closed-Loop Trial were used. Training data included 3 months of CGM recordings from 125 individuals with type 1 diabetes, and HbA1c at 3 months; testing data included 9 months of CGM recordings from 168 individuals, and HbA1c at 3, 6, and 9 months. Hemoglobin glycation was modeled by a first-order differential equation driven by TIR. Three model parameters were estimated in the training data set and fixed thereafter. A fourth parameter was estimated in the testing data set, to individualize the model by calibration with month 3 HbA1c. The accuracy of eA1c was assessed on months 6 and 9 HbA1c. Results: eA1c was tracked for each individual in the testing data set for 6 months after calibration. Mean absolute differences between HbA1c and eA1c 3- and 6-month postcalibration were 0.25% and 0.24%; Pearson's correlation coefficients were 0.93 and 0.93; percentages of eA1c within 10% from reference HbA1c were 97.6% and 96.3%, respectively. Conclusions: HbA1c and TIR are reflections of the same underlying process of glycemic fluctuation. Using a model individualized with one HbA1c measurement, TIR provides an accurate approximation of HbA1c for at least 6 months, reflecting blood glucose fluctuations and nonglycemic biological factors. Thus, eA1c is an intermediate metric that mathematically adjusts a CGM-based assessment of glycemic control to individual glycation rates.

Keywords: Continuous glucose monitoring; Estimated A1c; Hemoglobin A1c; Hemoglobin clearance; Hemoglobin glycation; International Diabetes Closed-Loop Trial; Time in range.

PubMed Disclaimer

Conflict of interest statement

No competing financial interests exist.

Figures

FIG. 1.
FIG. 1.
(Left panel) Correlation between TIR and HbA1c at month 6 (dark gray solid squares) and month 9 (light gray open triangles) of the study. (Right panel) Correlation between eA1c and HbA1c at month 6 (i.e., 3-month postcalibration; dark gray solid squares) and month 9 (i.e., 6-month postcalibration; light gray open triangles) of the study. Fitted linear regression models are shown for the four analyses, with the equations and RMSE values reported in the legends. eA1c, estimated A1c; HbA1c, hemoglobin A1c; RMSE, root mean squared error; TIR, time in target range.
FIG. 2.
FIG. 2.
Effect of the amount of CGM data before model calibration on method performance. (Left panel) Correlation and R2 between eA1c and HbA1c 3 months (dark gray solid squares) and 6 months (light gray open triangles) postcalibration. (Right panel) MAD between eA1c and HbA1c 3 months (dark gray solid squares) and 6 months (light gray open triangles) postcalibration. CGM, continuous glucose monitoring; MAD, mean absolute difference; R2, coefficient of determination.

Similar articles

Cited by

References

    1. Diabetes Control and Complications Trial Research Group. The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus. N Engl J Med 1993;329:977–986 - PubMed
    1. Diabetes Control and Complications Trial Research Group. The relationship of glycemic exposure (HbA1c) to the risk of development and progression of retinopathy in the Diabetes Control and Complications Trial. Diabetes 1995;44:968–983 - PubMed
    1. Welsh KJ, Kirkman MS, Sacks DB. Role of glycated proteins in the diagnosis and management of diabetes: research gaps and future directions. Diabetes Care 2016;39:1299–1306 - PMC - PubMed
    1. Hirsch IB. Glycemic variability: it's not just about A1C anymore! Diabetes Technol Ther 2005;7:780–783 - PubMed
    1. Brownlee M, Hirsch IB. Glycemic variability: a hemoglobin A1c-independent risk factor for diabetic complications. JAMA 2006;295:1707–1708 - PubMed

Publication types