Soft tissue artifact causes underestimation of hip joint kinematics and kinetics in a rigid-body musculoskeletal model

J Biomech. 2020 Jul 17:108:109890. doi: 10.1016/j.jbiomech.2020.109890. Epub 2020 Jun 13.

Abstract

Rigid body musculoskeletal models have been applied to study kinematics, moments, muscle forces, and joint reaction forces in the hip. Most often, models are driven with segment motions calculated through optical tracking of markers adhered to the skin. One limitation of optical tracking is soft tissue artifact (STA), which occurs due to motion of the skin surface relative to the underlying skeleton. The purpose of this study was to quantify differences in musculoskeletal model outputs when tracking body segment positions with skin markers as compared to bony landmarks measured by direct imaging of bone motion with dual fluoroscopy (DF). Eleven asymptomatic participants with normally developed hip anatomy were imaged with DF during level treadmill walking at a self-selected speed. Hip joint kinematics and kinetics were generated using inverse kinematics, inverse dynamics, static optimization and joint reaction force analysis. The effect of STA was assessed by comparing the difference in estimates from simulations based on skin marker positions (SM) versus virtual markers on bony landmarks from DF. While patterns were similar, STA caused underestimation of kinematics, range of motion (ROM), moments, and reaction forces at the hip, including flexion-extension ROM, maximum internal rotation joint moment and peak joint reaction force magnitude. Still, kinetic differences were relatively small, and thus they may not be relevant nor clinically meaningful.

Keywords: Gait; Motion capture; Musculoskeletal model; Simulation; X-ray.

Publication types

  • Research Support, N.I.H., Extramural
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Artifacts*
  • Biomechanical Phenomena
  • Gait
  • Hip Joint*
  • Humans
  • Kinetics
  • Range of Motion, Articular