A Case of Lower-Pole Moiety Ureteral Stenosis Close to Ureteropelvic Junction in an Incomplete Duplicated Collecting System Managed by Retrograde Balloon Dilatation that Needed a 2nd Ureteral Stent to the Upper-Pole

Case Rep Urol. 2020 Jul 16:2020:8835213. doi: 10.1155/2020/8835213. eCollection 2020.

Abstract

A 71-year-old woman presented at our institution with the chief complaints of left back pain and fatigue. Radiographic examination revealed left ureteral stenosis close to ureteropelvic junction of the lower-pole with a left incomplete duplicated collecting system. Transurethral retrograde balloon dilatation under general anesthesia was performed, and a ureteral stent was inserted to the lower-pole; however, there was urinary leakage from the upper-pole at the dilated ureteral stenosis lesion, and therefore, another ureteral stent was inserted to the upper-pole just after the first stent insertion. Both stents were removed at 6 weeks and subsequent intravenous pyelography confirmed resolution of the obstruction. The patient has remained asymptomatic during 2 years of follow-up.

Publication types

  • Case Reports