Abstract
The estimation of human ankle's mechanical impedance is an important tool for modeling human balance. This work presents the implementation of a parameter-estimation approach based on a state-augmented extended Kalman filter (AEKF) to infer the ankle's mechanical impedance during quiet standing. However, the AEKF filter is sensitive to the initialization of the noise covariance matrices. In order to avoid a time-consuming trial-and-error method and to obtain a better estimation performance, a genetic algorithm (GA) is proposed to best tune the measurement noise (Rk) and process noise covariances (Q) of the extended Kalman filter (EKF). Results using simulated data show the efficacy of the proposed algorithm for parameter-estimation of a third-order biomechanical model. Experimental validation of these results is also presented. They suggest that age is an influencing factor in the human balance.
Copyright © 2021 by ASME.
Similar articles
-
Fuzzy Adaptive Cubature Kalman Filter for Integrated Navigation Systems.Sensors (Basel). 2016 Jul 26;16(8):1167. doi: 10.3390/s16081167. Sensors (Basel). 2016. PMID: 27472336 Free PMC article.
-
Multibody-Based Input and State Observers Using Adaptive Extended Kalman Filter.Sensors (Basel). 2021 Aug 3;21(15):5241. doi: 10.3390/s21155241. Sensors (Basel). 2021. PMID: 34372478 Free PMC article.
-
Real-Time Speed Estimation for an Induction Motor: An Automated Tuning of an Extended Kalman Filter Using Voltage-Current Sensors.Sensors (Basel). 2024 Mar 7;24(6):1744. doi: 10.3390/s24061744. Sensors (Basel). 2024. PMID: 38544007 Free PMC article.
-
Joint kinematics estimation using a multi-body kinematics optimisation and an extended Kalman filter, and embedding a soft tissue artefact model.J Biomech. 2017 Sep 6;62:148-155. doi: 10.1016/j.jbiomech.2017.04.033. Epub 2017 May 17. J Biomech. 2017. PMID: 28551098
-
A review of the STAR prosthetic system and the biomechanical considerations in total ankle replacements.Foot Ankle Surg. 2011 Jun;17(2):64-7. doi: 10.1016/j.fas.2011.02.003. Epub 2011 Apr 2. Foot Ankle Surg. 2011. PMID: 21549974 Review.
Cited by
-
Intrinsic protein disorder is insufficient to drive subnuclear clustering in embryonic transcription factors.Elife. 2024 Jan 26;12:RP88221. doi: 10.7554/eLife.88221. Elife. 2024. PMID: 38275292 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources