ESTIMATION OF THERMAL POWER PLANT WORKERS EXPOSURE TO MAGNETIC FIELDS AND SIMULATION OF HAZARD ZONES

Radiat Prot Dosimetry. 2020 Sep 16;190(3):289-296. doi: 10.1093/rpd/ncaa101.

Abstract

Extremely low-frequency magnetic fields (ELF-MFs) have raised some concerns due to their possible effects on workers' health. In this study ELF-MFs were measured in different units of the thermal power plant based on gridding the indoor space. The exposure level was measured by spot measurement based on the IEEE Std C95.3.1 and then simulated in units with the highest magnetic field intensity by using ArcGIS software. The operators and balance of plant (BOP) technicians (12.64 ± 9.74 μT) and office workers (2.41 ± 1.22 μT) had the highest and lowest levels of both measured and estimated ELF-MFs exposure. The highest measured ELF-MFs were in the vicinity of the power transmission lines in the transformers' building (48.2 μT). Our simulation showed the high and low exposure areas and ranked exposure well; but, the actual measurements of ELF-MFs exposure were in all cases higher than the estimated values, which means we still need to improve our estimations.

MeSH terms

  • Electric Power Supplies
  • Electromagnetic Fields* / adverse effects
  • Humans
  • Magnetic Fields
  • Occupational Health*
  • Power Plants