Heparin-bonded versus standard polytetrafluoroethylene arteriovenous grafts: A Bayesian perspective on a randomized controlled trial for comparative effectiveness

Surgery. 2020 Dec;168(6):1066-1074. doi: 10.1016/j.surg.2020.07.013. Epub 2020 Aug 26.

Abstract

Background: Heparin-bonded polytetrafluoroethylene grafts were marketed to improve hemodialysis access outcomes but are twice the cost of standard polytetrafluoroethylene. We launched a randomized trial of heparin-bonded polytetrafluoroethylene versus standard polytetrafluoroethylene for hemodialysis access to compare patency. Since the trial began, additional studies were published with heterogeneous findings. We performed an interim analysis by Bayesian methods using prior probability from meta-analysis of existing literature.

Methods: NCT01601873 is a randomized, blinded trial of heparin-bonded polytetrafluoroethylene versus standard polytetrafluoroethylene for dialysis access at 5 sites. Planned sample size was 200 with 1-year primary patency as the primary endpoint. At interim analysis (50% of sample size at 1 year), we also performed a meta-analysis for 1-year primary patency with a random effects model to compute summary rate ratio and standard-error estimates. Meta-analysis estimates formed a prior probability for a Bayesian Cox regression model, and trial data were reanalyzed to develop posterior probability of heparin-bonded polytetrafluoroethylene effectiveness at our hypothesized effect size. Futility analysis was conducted using posterior probability estimates.

Results: One hundred and five patients were enrolled at the time of interim analysis. One-year primary patency was 34.9% in the heparin-bonded-polytetrafluoroethylene group vs 32.7% in the standard-polytetrafluoroethylene group (P = .884). Summary rate ratio from the meta-analysis (1,209 patients) was 0.87 favoring heparin-bonded polytetrafluoroethylene (P = .33). Posterior hazard ratio from Cox regression was 0.90 (credible interval 0.70-1.13) favoring heparin-bonded polytetrafluoroethylene, which was not significant. Bayesian posterior probability of the a priori hypothesized 20% better patency with heparin-bonded polytetrafluoroethylene was 24%. Sample size to detect superiority with the small observed effect size would require about 3,800 subjects.

Conclusion: Current evidence does not demonstrate sufficiently large benefit of heparin-bonded polytetrafluoroethylene over standard polytetrafluoroethylene for dialysis access to justify higher cost. Given similar 1-year patency rates, a conclusive finding of superiority was judged to be infeasible, and the trial was stopped for futility.

Publication types

  • Comparative Study
  • Equivalence Trial
  • Randomized Controlled Trial

MeSH terms

  • Aged
  • Anticoagulants / pharmacology
  • Bayes Theorem
  • Blood Vessel Prosthesis / adverse effects*
  • Blood Vessel Prosthesis Implantation / adverse effects*
  • Blood Vessel Prosthesis Implantation / instrumentation
  • Blood Vessel Prosthesis Implantation / statistics & numerical data
  • Female
  • Follow-Up Studies
  • Graft Occlusion, Vascular / etiology
  • Graft Occlusion, Vascular / prevention & control*
  • Graft Survival
  • Heparin / pharmacology
  • Humans
  • Kidney Failure, Chronic / therapy*
  • Male
  • Medical Futility
  • Middle Aged
  • Polytetrafluoroethylene
  • Prosthesis Design
  • Renal Dialysis / instrumentation*
  • Reoperation / statistics & numerical data
  • Treatment Outcome
  • Vascular Patency / drug effects

Substances

  • Anticoagulants
  • Polytetrafluoroethylene
  • Heparin