A pilot study of 13N-ammonia cardiac PET imaging to assess subacute cardiotoxicity following adjuvant intensity-modulated radiotherapy for locally advanced breast cancer

Clin Imaging. 2020 Dec:68:283-290. doi: 10.1016/j.clinimag.2020.07.026. Epub 2020 Aug 27.

Abstract

Objective: (1) Assess the feasibility of 13 N-ammonia cardiac PET (13 N-ammonia-PET) imaging in radiotherapy (RT) treatment position in locally-advanced breast cancer (LABC) patients. (2) Correlate pre-/post-RT changes in myocardial flow reserve (MFR) with the corresponding radiation heart dose.

Methods: Ten left-sided LABC patients undergoing Volumetric Modulated-Arc-Therapy (VMAT) to chest wall and regional lymph nodes underwent a rest/stress 13 N-ammonia-PET at baseline and (median) 13 months post-RT. Changes in cardiac functions and coronary artery Ca2+ scoring between baseline and follow-up were correlated with average RT dose to the myocardium,3 coronary territories, and 17 myocardial segments.

Results: Eight (of 10) patients successfully completed the study. The average rest (stress) global MBF (ml.g-1.min-1) for baseline (follow-up) were 0.83 ± 0.25 (2.4 ± 0.79) and 0.92 ± 0.30 (2.76 ± 0.71), respectively. Differences in MBF, heart rate, blood pressure, and rate-pressure product (RPP) between baseline and follow-up were insignificant (P > 0.1).Strong (R = 0.79; P < 0.01) and moderate (R = 0.53; P = 0.37) correlation existed between MBF Rest and MBF Stress, and RPP respectively. Four patients showed a reduction in MFR of up to ~41% in follow-up studies, increasing to ~52% in myocardial segments close to high-radiation isodose lines in 5/8 patients. Agatston Ca + 2 scoring were zero in both baseline and follow-up in six patients; two patients exhibited mild increase in Ca + 2 on follow-ups (range:10-20).Rest and stress LVEF's were normal (>50) for all patients in both studies.

Conclusion: The feasibility of 13 N-ammonia-PET imaging in treatment position of LABC patients was demonstrated. MFR at 1-year post-irradiation of the heart decreased in 50% of the patients. MFR may be a potential index for early detection of cardiotoxicity in BC patients receiving RT to the chest wall.

Keywords: (13)N-Ammonia PET; Cardiotoxicity; Radiotherapy.

MeSH terms

  • Ammonia
  • Breast Neoplasms* / diagnostic imaging
  • Breast Neoplasms* / radiotherapy
  • Cardiotoxicity / diagnostic imaging
  • Coronary Circulation
  • Humans
  • Pilot Projects
  • Positron-Emission Tomography
  • Radiotherapy, Intensity-Modulated*

Substances

  • Ammonia