Artificial Intelligence-Enabled ECG Algorithm to Identify Patients With Left Ventricular Systolic Dysfunction Presenting to the Emergency Department With Dyspnea
- PMID: 32986471
- DOI: 10.1161/CIRCEP.120.008437
Artificial Intelligence-Enabled ECG Algorithm to Identify Patients With Left Ventricular Systolic Dysfunction Presenting to the Emergency Department With Dyspnea
Abstract
Background: Identification of systolic heart failure among patients presenting to the emergency department (ED) with acute dyspnea is challenging. The reasons for dyspnea are often multifactorial. A focused physical evaluation and diagnostic testing can lack sensitivity and specificity. The objective of this study was to assess the accuracy of an artificial intelligence-enabled ECG to identify patients presenting with dyspnea who have left ventricular systolic dysfunction (LVSD).
Methods: We retrospectively applied a validated artificial intelligence-enabled ECG algorithm for the identification of LVSD (defined as LV ejection fraction ≤35%) to a cohort of patients aged ≥18 years who were evaluated in the ED at a Mayo Clinic site with dyspnea. Patients were included if they had at least one standard 12-lead ECG acquired on the date of the ED visit and an echocardiogram performed within 30 days of presentation. Patients with prior LVSD were excluded. We assessed the model performance using area under the receiver operating characteristic curve, accuracy, sensitivity, and specificity.
Results: A total of 1606 patients were included. Median time from ECG to echocardiogram was 1 day (Q1: 1, Q3: 2). The artificial intelligence-enabled ECG algorithm identified LVSD with an area under the receiver operating characteristic curve of 0.89 (95% CI, 0.86-0.91) and accuracy of 85.9%. Sensitivity, specificity, negative predictive value, and positive predictive value were 74%, 87%, 97%, and 40%, respectively. To identify an ejection fraction <50%, the area under the receiver operating characteristic curve, accuracy, sensitivity, and specificity were 0.85 (95% CI, 0.83-0.88), 86%, 63%, and 91%, respectively. NT-proBNP (N-terminal pro-B-type natriuretic peptide) alone at a cutoff of >800 identified LVSD with an area under the receiver operating characteristic curve of 0.80 (95% CI, 0.76-0.84).
Conclusions: The ECG is an inexpensive, ubiquitous, painless test which can be quickly obtained in the ED. It effectively identifies LVSD in selected patients presenting to the ED with dyspnea when analyzed with artificial intelligence and outperforms NT-proBNP. Graphic Abstract: A graphic abstract is available for this article.
Keywords: artificial intelligence; cardiomyopathies; dyspnea; electrocardiogram; heart failure.
Comment in
-
Applying Artificial Intelligence to ECG Analysis: Promise of a Better Future.Circ Arrhythm Electrophysiol. 2020 Aug;13(8):e009111. doi: 10.1161/CIRCEP.120.009111. Epub 2020 Aug 4. Circ Arrhythm Electrophysiol. 2020. PMID: 32809878 No abstract available.
Similar articles
-
Left ventricular systolic dysfunction predicted by artificial intelligence using the electrocardiogram in Chagas disease patients-The SaMi-Trop cohort.PLoS Negl Trop Dis. 2021 Dec 6;15(12):e0009974. doi: 10.1371/journal.pntd.0009974. eCollection 2021 Dec. PLoS Negl Trop Dis. 2021. PMID: 34871321 Free PMC article.
-
Prospective validation of a deep learning electrocardiogram algorithm for the detection of left ventricular systolic dysfunction.J Cardiovasc Electrophysiol. 2019 May;30(5):668-674. doi: 10.1111/jce.13889. Epub 2019 Mar 10. J Cardiovasc Electrophysiol. 2019. PMID: 30821035
-
Detection of Right and Left Ventricular Dysfunction in Pediatric Patients Using Artificial Intelligence-Enabled ECGs.J Am Heart Assoc. 2024 Nov 5;13(21):e035201. doi: 10.1161/JAHA.124.035201. Epub 2024 Nov 4. J Am Heart Assoc. 2024. PMID: 39494568
-
Artificial intelligence enabled ECG screening for left ventricular systolic dysfunction: a systematic review.Heart Fail Rev. 2023 Mar;28(2):419-430. doi: 10.1007/s10741-022-10283-1. Epub 2022 Nov 8. Heart Fail Rev. 2023. PMID: 36344908 Free PMC article. Review.
-
Assessing the diagnostic test accuracy of natriuretic peptides and ECG in the diagnosis of left ventricular systolic dysfunction: a systematic review and meta-analysis.Br J Gen Pract. 2006 Jan;56(522):48-56. Br J Gen Pract. 2006. PMID: 16438815 Free PMC article. Review.
Cited by
-
AI derived ECG global longitudinal strain compared to echocardiographic measurements.Sci Rep. 2024 Nov 2;14(1):26458. doi: 10.1038/s41598-024-78268-8. Sci Rep. 2024. PMID: 39488646 Free PMC article.
-
Noninvasive biometric monitoring technologies for patients with heart failure.Heart Fail Rev. 2024 Oct 22. doi: 10.1007/s10741-024-10441-7. Online ahead of print. Heart Fail Rev. 2024. PMID: 39436486 Review.
-
Use of artificial intelligence-powered ECG to differentiate between cardiac and pulmonary pathologies in patients with acute dyspnoea in the emergency department.Open Heart. 2024 Oct 1;11(2):e002924. doi: 10.1136/openhrt-2024-002924. Open Heart. 2024. PMID: 39353705 Free PMC article.
-
Dynamic risk stratification of worsening heart failure using a deep learning-enabled implanted ambulatory single-lead electrocardiogram.Eur Heart J Digit Health. 2024 May 8;5(4):435-443. doi: 10.1093/ehjdh/ztae035. eCollection 2024 Jul. Eur Heart J Digit Health. 2024. PMID: 39081943 Free PMC article.
-
Artificial intelligence-based screening for cardiomyopathy in an obstetric population: A pilot study.Cardiovasc Digit Health J. 2024 Apr 5;5(3):132-140. doi: 10.1016/j.cvdhj.2024.03.005. eCollection 2024 Jun. Cardiovasc Digit Health J. 2024. PMID: 38989045 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources