Loss of endothelial cells in viral DNA-positive grafts after keratoplasty: a 2-year follow-up study

Br J Ophthalmol. 2022 Jan;106(1):26-31. doi: 10.1136/bjophthalmol-2020-317629. Epub 2020 Oct 14.

Abstract

Background: To compare endothelial loss between recipients who received viral DNA-positive grafts and controls 2 years after corneal transplantation.

Methods: We retrospectively analysed the clinical data and endothelial cell density of recipients of viral DNA-positive grafts and age-, sex-, aetiology- and operation-matched controls from April 2017 to July 2019 at the Peking University Third Hospital, Beijing, China.

Results: A total of 23/942 (2.44%) donor corneal buttons tested virus-positive by real-time PCR. A total of 27 recipients (except for 2 recipients) of viral DNA-positive grafts and 48 recipients of viral DNA-negative grafts were included in this study. Recipients of viral DNA-positive grafts had a higher endothelial cell (EC) loss rate post-penetrating keratoplasty and post-descemet stripping automated endothelial keratoplasty (p<0.05), but post-deep lamellar keratoplasty, the EC loss rate was similar to that of the controls. Recipients of herpes simplex virus-1-, cytomegalovirus- and varicella-zoster virus-positive grafts all had a higher EC loss rate than the controls during the 12- and 24-month follow-up periods (p<0.05).

Conclusion: We inferred that viruses might be hidden in corneal grafts and mainly incubate in the corneal endothelium. Viral DNA-positive grafts do not need to be replaced immediately and can be followed up for a long time.

Keywords: Cornea; Infection; Treatment surgery.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Corneal Diseases* / surgery
  • Corneal Transplantation*
  • DNA, Viral / genetics
  • Descemet Stripping Endothelial Keratoplasty*
  • Endothelial Cells
  • Endothelium, Corneal / surgery
  • Follow-Up Studies
  • Humans
  • Keratoplasty, Penetrating
  • Retrospective Studies

Substances

  • DNA, Viral