CT reconstruction with thick slices not only underestimates lymph node size but also reduces data reproducibility in colorectal cancer

Acta Radiol. 2021 Oct;62(10):1275-1282. doi: 10.1177/0284185120968569. Epub 2020 Oct 29.

Abstract

Background: Reliable size measurement of lymph node (LN) metastases is important for the evaluation of cancer treatment. However, image analyses without proper settings may result in inappropriate diagnoses and staging.

Purpose: To investigate whether reconstruction slice thickness in computed tomography (CT) affects measurements of LN size and reproducibility.

Material and methods: We analyzed 48 patients with histological diagnoses of sigmoid colon and rectal cancer who underwent contrast-enhanced CT colonography as part of a surgical treatment preparation. A board-certified radiologist selected 106 LNs whose short-axis diameter was ≥5 mm on 1-mm-thick images; the short-axis diameters were measured on 1- and 5-mm-thick images by the radiologist and residents and compared using Wilcoxon matched-pairs signed rank test. Data variation and reproducibility were evaluated using the F test and Bland-Altman analysis. P<0.05 was considered significant.

Results: Short-axis diameters measured on 5-mm-thick images were significantly lower than those measured on 1-mm-thick images (P<0.01), even in the LNs whose short-axis diameters were over twice the slice thickness (P<0.05). Of the 106 LNs, 57 showed short-axis diameter <5 mm on 5-mm-thick images; the maximum short-axis diameter was 6.7 mm on a 1-mm thick image. Data variation was significantly larger on 5-mm thick images than 1-mm-thick images in small LNs (P<0.05) and reproducibility on 5-mm-thick images was inferior to that on 1-mm-thick images.

Conclusion: Thick reconstruction slices in CT can result in an underestimation of LN size and reduce data reproducibility. When measuring LN size, a thin reconstruction slice would be recommended based on targeted LN size.

Keywords: Computed tomography; lymph node; reproducibility; short-axis diameter; slice thickness.

Publication types

  • Observational Study

MeSH terms

  • Adult
  • Aged
  • Aged, 80 and over
  • Colonography, Computed Tomographic / methods*
  • Colorectal Neoplasms / diagnostic imaging*
  • Colorectal Neoplasms / pathology*
  • Contrast Media
  • Female
  • Humans
  • Lymph Nodes / diagnostic imaging
  • Lymph Nodes / pathology
  • Lymphatic Metastasis / diagnostic imaging*
  • Male
  • Middle Aged
  • Radiographic Image Enhancement / methods
  • Radiographic Image Interpretation, Computer-Assisted / methods*
  • Reproducibility of Results

Substances

  • Contrast Media