Influence of Screw Channel Angulation on the Fracture Resistance of Zirconia Abutments: An In Vitro Study

J Prosthodont. 2021 Apr;30(4):329-334. doi: 10.1111/jopr.13275. Epub 2020 Nov 10.

Abstract

Purpose: The aim of this study was to investigate the effect of implant screw channel angulation on the fracture resistance of zirconia abutments without artificial aging.

Materials and methods: Ten implant replicas were embedded in a jig of autopolymerizing acrylic resin. Using a surveyor and a metallic platform, the implant replicas were mounted centrally and with an angulation of 30°. A maxillary left central incisor crown was fabricated from pattern resin and scanned. The digital design of a monolithic zirconia implant abutment-crown was completed using a 3D imaging software. For all specimens of this group (ASC25 ), the screw channel was positioned at 25° to the lingual. Following fabrication, the samples were attached onto the embedded implant replicas and manually torqued to 35 Ncm as recommended by the manufacturer. The monolithic zirconia implant abutment-crowns were mounted in a metallic platform, positioned perpendicular to the indenter, and subjected to loading until failure. Crosshead speed was set at 0.5 mm/min for the universal testing machine. Data from a similar in vitro study where straight zirconia custom abutments (ASC0 ) were subjected to static load until failure was used as a control group. An unpaired Student's t-test was used to determine if fracture resistance based on load at failure and maximum load in each group were significantly different from each other (ASC25 vs ASC0 ). Statistical significance level was inferred at p ≤ 0.05 RESULTS: Group ASC25 fractured at a mean (SD) load of 215.49 (47.10) N and a mean (SD) maximum load of 420.50 (17.18) N. Group ASC0 fractured at a mean (SD) load of 534.04 (133.77) N and a mean (SD) maximum load of 762.69 (109.59) N. The difference was statistically significant for both mean load and mean maximum load at failure (p ≤ 0.05). The survival rate of 0° zirconia abutments was significantly higher than that of 25° ASC zirconia abutments.

Conclusions: Within the limitations of this in vitro study the mean fracture load was significantly higher in the group with a straight channel angulation.

Keywords: Two-piece abutments; angulated screw channel; anterior restorations; fracture; zirconia abutments.

MeSH terms

  • Bone Screws
  • Computer-Aided Design
  • Crowns
  • Dental Abutments*
  • Dental Implant-Abutment Design*
  • Dental Restoration Failure
  • Dental Stress Analysis
  • Humans
  • Materials Testing
  • Titanium
  • Zirconium

Substances

  • Zirconium
  • Titanium
  • zirconium oxide