Objectives: In this work, a simple and rapid liquid chromatographic method for the simultaneous determination of irbesartan (IRBE) and hydrochlorothiazide (HCT) was developed and validated by reverse phase high performance liquid chromatography (RP-HPLC).
Materials and methods: Experimental conditions such as different buffer solutions, various pH values, temperature, composition of the mobile phase, and the effect of flow rate were optimized.
Results: The developed RP-HPLC method for these antihypertensive agents was wholly validated and IRBE was detected in the linear range of 0.1-25 μg mL-1 and HCT was detected in the linear range of 0.25-25 μg mL-1. Moreover, the suggested chromatographic technique was successfully applied for the determination of the drugs in human serum and pharmaceutical dosage forms with limit of detection values of 0.008 μg mL-1 for IRBE and 0.012 μg mL-1 for HCT.
Conclusion: The proposed rapid analysis method of these antihypertensive drugs can be easily used and applied by pharmaceutical companies for which the analysis time is important.
Keywords: HPLC; hydrochlorothiazide; irbesartan; pharmaceutical dosage forms.
©Copyright 2020 Turk J Pharm Sci, Published by Galenos Publishing House.