Introduction: Venous anastomosis remains to be a challenging step in microsurgical tissue transfer and venous complications constitute to a common reason for free flap failure. While several studies have compared mechanical vs. hand-sewn venous anastomoses, there is no large-series study comparing the type of anastomosis exclusively in DIEP flap breast reconstructions.
Patients and methods: Between 2011 and 2019, 3926 female patients underwent 4577 free DIEP-flap breast reconstructions in 22 different breast cancer centers. Patient data was collected via an online database, files were screened and cases were divided into a hand- (HA) and a coupler-anastomosis (CA) group. Complications were accounted for and the two groups were then compared.
Results: Mean ischemia time was significantly shorter in the CA group (46.88 ± 26.17 vs. 55.48 ± 24.70 min; p < .001), whereas mean operative time was comparable (316 ± 134.01 vs. 320.77 ± 120.29 minutes; p = .294). We found no significant difference between both groups regarding the rate of partial (CA: 1.0% vs. HA: 1.3%) and total flap loss (CA: 2.2% vs. HA: 1.8%). However, revision rates were significantly higher in the CA group (CA: 10.5% vs. HA: 7.9%; p = .003), with higher numbers of arterial (2.3 vs. 0.9%; p < .001) and venous thromboses (3.4 vs. 1.8%; p = .001) accounting for this finding.
Conclusions: All taken into account, our findings do support the feasibility of venous coupler anastomoses in principle, however the inflationary use of coupler devices should be evaluated critically.