Transcatheter Pulmonary Valve Replacement With the Sapien Prosthesis

J Am Coll Cardiol. 2020 Dec 15;76(24):2847-2858. doi: 10.1016/j.jacc.2020.10.041.

Abstract

Background: There are limited published data focused on outcomes of transcatheter pulmonary valve replacement (TPVR) with either a Sapien XT or Sapien 3 (S3) valve.

Objectives: This study sought to report short-term outcomes in a large cohort of patients who underwent TPVR with either a Sapien XT or S3 valve.

Methods: Data were entered retrospectively into a multicenter registry for patients who underwent attempted TPVR with a Sapien XT or S3 valve. Patient-related, procedural, and short-term outcomes data were characterized overall and according to type of right ventricular outflow tract (RVOT) anatomy.

Results: Twenty-three centers enrolled a total of 774 patients: 397 (51%) with a native/patched RVOT; 183 (24%) with a conduit; and 194 (25%) with a bioprosthetic valve. The S3 was used in 78% of patients, and the XT was used in 22%, with most patients receiving a 29-mm (39%) or 26-mm (34%) valve. The implant was technically successful in 754 (97.4%) patients. Serious adverse events were reported in 67 patients (10%), with no difference between RVOT anatomy groups. Fourteen patients underwent urgent surgery. Nine patients had a second valve implanted. Among patients with available data, tricuspid valve injury was documented in 11 (1.7%), and 9 others (1.3%) had new moderate or severe regurgitation 2 grades higher than pre-implantation, for 20 (3.0%) total patients with tricuspid valve complications. Valve function at discharge was excellent in most patients, but 58 (8.5%) had moderate or greater pulmonary regurgitation or maximum Doppler gradients >40 mm Hg. During limited follow-up (n = 349; median: 12 months), 9 patients were diagnosed with endocarditis, and 17 additional patients underwent surgical valve replacement or valve-in-valve TPVR.

Conclusions: Acute outcomes after TPVR with balloon-expandable valves were generally excellent in all types of RVOT. Additional data and longer follow-up will be necessary to gain insight into these issues.

Keywords: Sapien S3; Sapien XT; tetralogy of Fallot.

Publication types

  • Multicenter Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adolescent
  • Adult
  • Bioprosthesis
  • Child
  • Endovascular Procedures / instrumentation
  • Endovascular Procedures / methods
  • Endovascular Procedures / statistics & numerical data*
  • Female
  • Heart Valve Prosthesis Implantation / instrumentation
  • Heart Valve Prosthesis Implantation / methods
  • Heart Valve Prosthesis Implantation / statistics & numerical data*
  • Heart Valve Prosthesis*
  • Humans
  • Male
  • Middle Aged
  • Pulmonary Valve*
  • Registries*
  • Retrospective Studies
  • Young Adult