Long-Term Follow-Up of Percutaneous Coronary Intervention With Paclitaxel-Eluting Balloon Catheter

Angiology. 2021 Apr;72(4):364-370. doi: 10.1177/0003319720979246. Epub 2020 Dec 17.

Abstract

Drug-eluting balloons currently constitute a therapeutic tool used in percutaneous coronary interventions (PCI). Long-term results remain unknown. We evaluated the prognosis of PCI using a second generation paclitaxel-eluting balloon (PEB) in real-world patients. We included all PCI with PEB in de novo or in-stent restenosis coronary lesions performed in our unit from March 2009 to March 2019. We assessed the composite of major adverse cardiovascular events (MACE) rate after a median follow-up of 42 months. Consecutive patients (n = 320) with 386 lesions were included; 46.9% presented with stable angina and 53.1% acute coronary syndromes; 52.6% of the lesions were in-stent restenosis and 47.3% de novo lesions with a mean diameter of 2.4 ± 0.5 mm. A bare metal stent was implanted in 6.7% and a drug-eluting stent in 8.5% of patients. The MACE rate was 8%: 10 (2.6%) cardiovascular deaths, 13 (3.4%) myocardial infarctions, and 16 (4.1%) target lesion revascularization. The all-cause death rate was 5.2%. No cases of thrombosis were recorded. In conclusion, PEB was a safe and effective tool to treat in-stent restenosis and de novo coronary lesions, especially small vessel disease, during long-term follow-up.

Keywords: drug-eluting balloon; in-stent restenosis; percutaneous coronary intervention; small vessel disease.

Publication types

  • Observational Study

MeSH terms

  • Acute Coronary Syndrome / diagnostic imaging
  • Acute Coronary Syndrome / mortality
  • Acute Coronary Syndrome / therapy*
  • Aged
  • Angioplasty, Balloon, Coronary / adverse effects
  • Angioplasty, Balloon, Coronary / instrumentation*
  • Angioplasty, Balloon, Coronary / mortality
  • Cardiac Catheters*
  • Cardiovascular Agents / adverse effects
  • Cardiovascular Agents / therapeutic use*
  • Coated Materials, Biocompatible*
  • Coronary Artery Disease / diagnostic imaging
  • Coronary Artery Disease / mortality
  • Coronary Artery Disease / therapy*
  • Coronary Restenosis / diagnostic imaging
  • Coronary Restenosis / mortality
  • Coronary Restenosis / therapy*
  • Equipment Design
  • Female
  • Humans
  • Male
  • Middle Aged
  • Paclitaxel / adverse effects
  • Paclitaxel / therapeutic use*
  • Prospective Studies
  • Time Factors
  • Treatment Outcome

Substances

  • Cardiovascular Agents
  • Coated Materials, Biocompatible
  • Paclitaxel