Dual-energy computed tomography vs ultrasound, alone or combined, for the diagnosis of gout: a prospective study of accuracy

Rheumatology (Oxford). 2021 Oct 2;60(10):4861-4867. doi: 10.1093/rheumatology/keaa923.

Abstract

Objective: To examine the accuracy of dual-energy CT (DECT) vs ultrasound or their combination for the diagnosis of gout.

Methods: Using prospectively collected data from an outpatient rheumatology clinic at a tertiary-care hospital, we examined the diagnostic accuracy of either modality alone or their combination, by anatomical site (feet/ankles and/or knees), for the diagnosis of gout. We used two standards: (i) demonstration of monosodium urate crystals in synovial fluid (gold), and (ii) modified (excluding DECT and ultrasound) 2015 ACR-EULAR gout classification criteria (silver).

Results: Of the 147 patients who provided data, 48 (33%) had synovial fluid analysis performed (38 were monosodium urate-crystal positive) and mean symptom duration was 9.2 years. One hundred (68%) patients met the silver standard. Compared with the gold standard, diagnostic accuracy statistics for feet/ankles DECT, feet/ankles ultrasound, knees DECT and knees ultrasound were, respectively: sensitivity: 87%, 84%, 91% and 58%; specificity: 100%, 60%, 87% and 80%; positive predictive value: 100%, 89%, 97% and 92%; negative predictive value: 67%, 50%, 70% and 33%; area under the receiver operating characteristic curve: 0.93, 0.72, 0.89 and 0.66. Combining feet/ankles DECT with ultrasound or knees DECT with ultrasound led to a numerically higher sensitivity compared with DECT alone, but overall accuracy was lower. Similarly, combining imaging knees to feet/ankles also yielded a numerically higher sensitivity and negative predictive values compared with feet/ankles DECT alone, without differences in overall accuracy. Findings were replicated compared with the silver standard, but with lower numbers.

Conclusions: Feet/ankles or knees DECT alone had the best overall accuracy for gout diagnosis. The DECT-US combination or multiple joint imaging offered no additional increase in overall diagnostic accuracy.

Keywords: accuracy; diagnosis; dual-energy computed tomography; gout; predictive value; sensitivity; specificity; ultrasound.

Publication types

  • Comparative Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adult
  • Aged
  • Female
  • Gout / diagnosis
  • Gout / diagnostic imaging*
  • Humans
  • Male
  • Middle Aged
  • Prospective Studies
  • Reproducibility of Results
  • Sensitivity and Specificity
  • Tomography, X-Ray Computed* / methods
  • Ultrasonography* / methods