Improved access in minimally invasive temporomandibular joint surgery through a novel endaural template

BMC Surg. 2021 Feb 19;21(1):93. doi: 10.1186/s12893-021-01098-2.

Abstract

Background: Digitally designed surgical templates for minimally invasive temporomandibular joint (TMJ) surgery (MITMJS) are a promising tool for improving the safety of these procedures. Given the TMJ anatomy, the template fitting and intraoperative overview are the most important issues for a safe surgery. This article is a technical advance article that aims to describe an endaural surgical template based on the Moses approach as a possible solution in TMJ surgery.

Methods: Three patients with internal derangement were treated with the guidance of a MITMJS template based on cone beam computed tomography (CBCT) and a surface imprint of the periauricular region. None of the patients needed an additional open surgical procedure. Fitting of the templates was judged in terms of position and rotational stability. Surgical side effects and complications were recorded for each patient.

Results: The template design and clinical use were satisfactory for MITMJS. The templates showed satisfying fit and good visibility. In the study cohort, no bleeding, facial nerve injury, or other complications occurred after the procedure, and no visible scars were noted postoperatively.

Conclusion: Our feasibility report on template-guided MITMJS shows a promising new application of templates. It points to improved access in arthroscopy or arthrocentesis of TMJ surgery through endaural access with an increased level of safety during surgery.

Keywords: Endaural template; Minimally invasive temporomandibular joint surgery; TMJ surgery; Template.

MeSH terms

  • Feasibility Studies
  • Humans
  • Minimally Invasive Surgical Procedures* / methods
  • Temporomandibular Joint Disorders* / surgery