Magnetic Resonance Imaging 1 Year After Hamstring Autograft Anterior Cruciate Ligament Reconstruction Can Identify Those at Higher Risk of Graft Failure: An Analysis of 250 Cases

Am J Sports Med. 2021 Apr;49(5):1270-1278. doi: 10.1177/0363546521995512. Epub 2021 Feb 25.

Abstract

Background: There is currently no analysis of 1-year postoperative magnetic resonance imaging (MRI) that reproducibly evaluates the graft of a hamstring autograft anterior cruciate ligament reconstruction (ACLR) and helps to identify who is at a higher risk of graft rupture upon return to pivoting sports.

Purpose: To ascertain whether a novel MRI analysis of ACLR at 1 year postoperatively can be used to predict graft rupture, sporting level, and clinical outcome at a 1-year and minimum 2-year follow-up.

Study design: Case-control study; Level of evidence, 3.

Methods: Graft healing and integration after hamstring autograft ACLR were evaluated using the MRI signal intensity ratio at multiple areas using oblique reconstructions both parallel and perpendicular to the graft and tunnel apertures. Clinical outcomes were assessment of side-to-side laxity and International Knee Documentation Committee (IKDC) Subjective Knee Evaluation Form, Lysholm, and Tegner activity level scores at 1 year. Repeat outcome measures and detection of graft rupture were evaluated at a minimum of 2 years.

Results: A total of 250 patients (42.4% female) underwent MRI analysis at 1 year, and assessment of 211 patients between 1 year and the final follow-up (range, 24-36 months) detected 9 graft ruptures (4.3%; 5 in female patients). A significant predictor for graft rupture was a high signal parallel to the proximal intra-articular graft and perpendicular to the femoral tunnel aperture (P = .032 and P = .049, respectively), with each proximal graft signal intensity ratio (SIR) increase by 1 corresponding to a 40% increased risk of graft rupture. A cutoff SIR of 4 had a sensitivity and specificity of 66% and 77%, respectively, in the proximal graft and 88% and 60% in the femoral aperture. In all patients, graft signal adjacent to and within the tibial tunnel aperture, and in the mid intra-articular portion, was significantly lower than that for the femoral aperture (P < .001). A significant correlation was seen between the appearance of higher graft signal on MRI and those patients achieving top sporting levels by 1 year.

Conclusion: ACLR graft rupture after 1 year is associated with MRI appearances of high graft signal adjacent to and within the femoral tunnel aperture. Patients with aspirations of quickly returning to a high sporting level may benefit from MRI analysis of graft signal. Graft signal was highest at the femoral tunnel aperture, adding further radiographic evidence that the rate-limiting step to graft healing occurs proximally.

Keywords: ACL; MRI; Tegner activity level; adjustable suspensory fixation; hamstring autograft; reconstruction.

MeSH terms

  • Anterior Cruciate Ligament Injuries* / diagnostic imaging
  • Anterior Cruciate Ligament Injuries* / surgery
  • Anterior Cruciate Ligament Reconstruction*
  • Autografts / surgery
  • Case-Control Studies
  • Female
  • Hamstring Tendons* / diagnostic imaging
  • Humans
  • Knee Joint / surgery
  • Magnetic Resonance Imaging
  • Male
  • Transplantation, Autologous
  • Treatment Outcome